de Lange E E, Mugler J P, Gay S B, DeAngelis G A, Berr S S, Harris E K
Department of Radiology, University of Virginia Health Sciences Center, Charlottesville 22908, USA.
Radiology. 1996 Aug;200(2):465-73. doi: 10.1148/radiology.200.2.8685343.
To compare breath-hold T1-weighted magnetization-prepared gradient-echo (MP-GRE) magnetic resonance (MR) imaging with contrast material-enhanced computed tomography (CT) in the assessment of focal liver disease.
The MR and CT images obtained in 64 patients with focal liver disease were reviewed by six independent reviewers in a randomized, blinded fashion. Sets of axial T1-weighted MP-GRE images, three-plane (a compilation of axial, sagittal, and coronal) T1-weighted MP-GRE images, and contrast-enhanced CT scans were analyzed. T2-weighted spin-echo (SE) MR images were also compared with CT scans.
Lesions were detected, localized, and characterized more accurately and generally with greater confidence with three-plane T1-weighted MP-GRE imaging than with CT (P < .01). Axial T1-weighted MP-GRE imaging was also superior (P < .05) to CT (although slightly less superior than three-plane imaging) except in the characterization of specific lesions, where both techniques were equal. T2-weighted SE MR imaging and CT were about equal.
Lesion detection, localization, and characterization are performed more accurately and confidently with breath-hold T1-weighted MP-GRE imaging than with contrast-enhanced CT, particularly when breath-hold images are obtained in three planes.
比较屏气T1加权磁化准备梯度回波(MP-GRE)磁共振(MR)成像与对比剂增强计算机断层扫描(CT)在评估局灶性肝病中的应用。
64例局灶性肝病患者的MR和CT图像由6名独立的阅片者以随机、盲法进行回顾性分析。分析了轴位T1加权MP-GRE图像、三平面(轴位、矢状位和冠状位合成)T1加权MP-GRE图像以及对比增强CT扫描图像。还将T2加权自旋回波(SE)MR图像与CT扫描图像进行了比较。
与CT相比,三平面T1加权MP-GRE成像在检测、定位和特征描述病变方面更准确,且总体上信心更强(P <.01)。轴位T1加权MP-GRE成像也优于CT(P <.05)(尽管略逊于三平面成像),但在特定病变的特征描述方面,两种技术相当。T2加权SE MR成像和CT大致相当。
与对比剂增强CT相比,屏气T1加权MP-GRE成像在病变检测、定位和特征描述方面更准确、更有信心,尤其是在获取三平面屏气图像时。