Wagner M, Wagner H
Orthopdische Klinik Wichernhaus-Rummelsberg, Schwarzenbruck/Nürnberg.
Orthopade. 1996 Apr;25(2):129-39.
In the era of successful total hip replacement, hip arthrodesis has become an infrequent surgical procedure. Current indications are severe deterioration of the hip joint with a painful, reduced range of motion in young patients, such as disorders subsequent to sepsis of the hip joint, slipped capital epiphysis, Perthes' disease and trauma with contraindications for a total joint replacement. Another important indication is paralysis or musculature loss. From 1980 to 1990, 20 consecutive patients underwent a hip arthrodesis with a cobra plate and were evaluated. None of the patients was lost for follow-up; complications occurred in 5 out of 25 cases (20%). All patients had radiographic evidence of union, 2 patients required re-osteosynthesis and bone grafting. In two cases infection occurred. In one case the position of the fused join went into abduction. Thirteen patients were able to walk free of pain; however, 5 patients were disappointed with the arthrodesis result because of the handicap involved with a fused hip. Hip arthrodesis using the cobra plate is a technically demanding operation, but immediate mobilization and partial weight bearing are facilitated. There is little risk of non-union compared to other surgical procedures. If the technique is correct functional problems will be rare.
在全髋关节置换术取得成功的时代,髋关节融合术已成为一种不常见的外科手术。目前的适应证是年轻患者髋关节严重退变伴疼痛、活动范围减小,如髋关节败血症、股骨头骨骺滑脱、佩特兹病及有全关节置换术禁忌证的创伤后的病症。另一个重要适应证是瘫痪或肌肉组织缺失。1980年至1990年,连续20例患者接受了用眼镜蛇钢板进行的髋关节融合术并进行了评估。无一例患者失访;25例中有5例(20%)出现并发症。所有患者均有影像学上的融合证据,2例患者需要再次骨固定和植骨。2例发生感染。1例融合关节位置出现外展。13例患者能够无痛行走;然而,5例患者因融合髋关节带来的残疾对融合术结果不满意。使用眼镜蛇钢板进行髋关节融合术是一项技术要求较高的手术,但有利于早期活动和部分负重。与其他外科手术相比,不愈合的风险较小。如果技术正确,功能问题将很少见。