Koplan B A, Beller G A, Ruiz M, Yang J Y, Watson D D, Glover D K
Department of Medicine, University of Virginia Health Sciences Center, Charlottesville 22908, USA.
J Nucl Med. 1996 Aug;37(8):1398-402.
Technetium-99m-tetrofosmin uptake was compared to that of 201Tl in the setting of low flow and systolic dysfunction.
In nine open-chested dogs, a severe left anterior descending (LAD) coronary artery stenosis resulted in a 54.3% mean flow reduction and decreased left ventricular thickening from 21% +/- 1% to -3 +/- 2%. After 30 min, 37 MBq (1 mCi) of 201Tl and microspheres were injected and initial and 2-hr redistribution images acquired. Two hours later, 370 MBq (10 mCi) of 99mTc-tetrofosmin and microspheres were injected and an image was obtained. LAD: left circumflex (LCX) count ratios for both tracers and flows were calculated by well counting postmortem, and 201Tl and 99mTc-tetrofosmin defect magnitudes were determined by quantitative image analysis.
LAD:LCx flow ratios were similar during 201Tl and 99mTc-tetrofosmin injections (0.48 +/- 0.04 versus 0.49 +/- 0.05, p = n.s.). Final 201Tl activity (0.66 +/- 0.04) was significantly higher than 99mTc-tetrofosmin (0.55 +/- 0.05; p < 0.05). LAD/LCx 99mTc-tetrofosmin image defect count ratio was similar to 201Tl defect count ratio on the initial rest 201Tl scan (0.57 +/- 0.03 versus 0.56 +/- 0.02, p = ns), but significantly less than 201Tl defect count ratio at 2 hr (0.57 +/- 0.03 versus 0.65 +/- 0.02, p < 0.05).
In a low-flow model with profound systolic dysfunction, myocardial 99mTc-tetrofosmin uptake ( > 50%) reflective of viability was observed in the asynergic zone perfused by the stenotic LAD.
在低血流和收缩功能障碍的情况下,比较了锝-99m-替曲膦与铊-201的摄取情况。
在9只开胸犬中,严重的左前降支(LAD)冠状动脉狭窄导致平均血流减少54.3%,左心室增厚从21%±1%降至-3±2%。30分钟后,注射37MBq(1mCi)的铊-201和微球,并采集初始和2小时再分布图像。两小时后,注射370MBq(10mCi)的锝-99m-替曲膦和微球,并获得一幅图像。通过死后井型计数计算两种示踪剂和血流的LAD:左旋支(LCX)计数比,并通过定量图像分析确定铊-201和锝-99m-替曲膦的缺损大小。
在注射铊-201和锝-99m-替曲膦期间,LAD:LCX血流比相似(0.48±0.04对0.49±0.05,p=无显著性差异)。最终铊-201活性(0.66±0.04)显著高于锝-99m-替曲膦(0.55±0.05;p<0.05)。在初始静息铊-201扫描时,锝-99m-替曲膦图像缺损计数比与铊-201缺损计数比相似(0.57±0.03对0.56±0.02,p=无显著性差异),但在2小时时显著低于铊-201缺损计数比(0.57±0.03对0.65±0.02,p<0.05)。
在严重收缩功能障碍的低血流模型中,在由狭窄的LAD灌注的无协同作用区域观察到反映存活心肌的锝-99m-替曲膦摄取(>50%)。