Evaluation of intramyocardial coronary blood flow waveform during intraaortic balloon pumping in the absence or presence of coronary stenosis.

作者信息

Toyota E, Songfang L, Kimura A, Hiramatsu O, Tachibana H, Chiba Y, Goto M, Ogasawara Y, Tsujioka K, Kajiya F

机构信息

Department of Medical Engineering and Systems Cardiology, Kawasaki Medical School, Okayama, Japan.

出版信息

Artif Organs. 1996 Feb;20(2):166-8. doi: 10.1111/j.1525-1594.1996.tb00722.x.

Abstract

Our aim was to evaluate the effects of intraaortic balloon pumping (IABP) on the blood velocity waveform in the absence or presence of coronary artery stenosis. Using anesthetized open-chest dogs, the septal arterial blood flow velocities were measured with a 20 MHz 80-channel ultrasound pulsed Doppler velocimeter in the absence (n = 5) or presence (n = 3) of left main coronary artery stenosis. The blood velocity waveform was analyzed by calculating the systolic retrograde velocity integral (SR) and the diastolic antegrade velocity integral (DA). A slosh ratio was defined as SR/DA. The left anterior descending arterial flow (CBF), aortic pressure (AoP), and poststenotic distal coronary pressure (DiP) were also measured simultaneously. We compared the effect of IABP on the velocity waveforms in the absence and in the presence of coronary artery stenosis. In the absence of stenosis, IABP increased DiP during diastole and augmented DA while it also increased SR. IABP augmented the net CBF because of the greater increase in DA than SR. In the presence of stenosis, however, IABP did not increase DiP and resulted in no significant effect on the net CBF.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验