Suppr超能文献

Use of a hypoxic lung as a deoxygenator to provide extended assessment of pulmonary function in rats.

作者信息

DeCampos K N, Keshavjee S H, Tremblay L, Yamashiro T, Slutsky A S

机构信息

Department of Surgery, Toronto Hospital, Ontario, Canada.

出版信息

J Appl Physiol (1985). 1996 May;80(5):1835-40. doi: 10.1152/jappl.1996.80.5.1835.

Abstract

Isolated perfused lung systems are commonly used to assess lung function in experimental studies. Assessment of hemodynamics and gas-exchange function in these systems is limited by the availability of venous blood. This study describes and validates a rat lung perfusion circuit in which a double-lung block ventilated with a hypoxic gas mixture [inspired O2 fraction (FIO2) 0.04; inspired CO2 fraction 0.08; deoxygenator (Deoxy) block] is used to provide blood with blood gases that are similar to mixed venous values to perfuse a study lung (FIO2 0.21; left lung only). This allows extended assessment of hemodynamics and gas exchange. Fifty adult male Wistar rats (300-400 g) were used as double-lung donors. Twenty-five perfusions (of both Deoxy and study lungs) were performed in four protocols (groups 1-5; n = 5). In protocol 1 (group 1), we tested whether exposure to room air affects the gas composition of the blood in the system. We found that the gas composition of the venous reservoir blood was identical to that of the blood entering the study block. In protocol 2, the effect of perfusion time and perfusion flow rate on the stability of the system was assessed. Lungs were perfused at 4 and 12 ml/min (groups 2 and 3, respectively), and the procedure was discontinued if edema or a marked decline in hemodynamics or gas-exchange function was observed. Pulmonary function was excellent and remained stable for 3 (at 12 ml/min) and 5 h (at 4 ml/min). In protocol 3, we examined whether hypoxic ventilation in the Deoxy lungs affects the stability of the system. Despite the low FIO2 used in the Deoxy lungs, the mean pulmonary arterial pressure-to-blood flow relationships in the study and Deoxy lungs were similar. Finally, in protocol 4, perfusion of a damaged study lung did not impair the function of the system. We conclude that this model permits reliable assessment of pulmonary function in rats under controlled ventilation and perfusion conditions. The use of a Deoxy double-lung block simplifies the perfusion apparatus and eliminates the main cause of instability of other systems that use an anesthetized host animal to provide venous blood.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验