In this study, we investigated the immunoreactivity of the Technicon Immuno 1 PSA assay, a monoclonal-polyclonal sandwich immunoassay, with free and ACT-complexed PSA. Assay calibrators prepared with free PSA (standard Immuno 1 calibrators) and calibrators consisting of 90% ACT-complexed and 10% free PSA (90:10 calibrators) yielded virtually identical PSA recoveries at all concentrations tested. Concentrations of total PSA at approximately 4 and 10 ng/mL, prepared in varying ratios of free PSA to PSA-ACT complex, recovered from 92-104% at 4 ng/mL and from 98-102% at 10 ng/mL. Additionally, an excellent correlation of serum total PSA values from a panel of 40 prostatic cancer patient samples was obtained using calibration curves generated with the standard Immuno 1 calibrators or the 90:10 calibrators. These results demonstrate that the Technicon Immuno 1 PSA assay measures free and ACT-complexed PSA on an equal molar basis.

摘要

在本研究中,我们调查了Technicon Immuno 1 PSA检测法(一种单克隆 - 多克隆夹心免疫测定法)对游离PSA和与α1 - 抗糜蛋白酶(ACT)结合的PSA的免疫反应性。用游离PSA制备的检测校准品(标准Immuno 1校准品)以及由90%与ACT结合的PSA和10%游离PSA组成的校准品(90:10校准品)在所有测试浓度下产生的PSA回收率几乎相同。以游离PSA与PSA - ACT复合物的不同比例制备的总PSA浓度约为4和10 ng/mL时,4 ng/mL的回收率为92 - 104%,10 ng/mL的回收率为98 - 102%。此外,使用标准Immuno 1校准品或90:10校准品生成的校准曲线,对40例前列腺癌患者样本的血清总PSA值进行检测,结果具有良好的相关性。这些结果表明,Technicon Immuno 1 PSA检测法在等摩尔基础上测定游离PSA和与ACT结合的PSA。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验