Greenberg R P, Mayer D J, Becker D P, Miller J D
J Neurosurg. 1977 Aug;47(2):150-62. doi: 10.3171/jns.1977.47.2.0150.
Methods for obtaining multimodality evoked potentials, somatosensory, visual, auditory, and auditory brain-stem potentials in patients with severe head trauma are described. A method of analyzing abnormal multimodality evoked potentials (graded evoked brain-injury potentials) is proposed that defines the degree of abnormality of the electrophysiological data and expresses it simply in four grades per modality. Data from 20 normal subjects are given for comparison with the abnormal data obtained from 51 patients with head trauma.
描述了在重度颅脑外伤患者中获取多模态诱发电位(体感诱发电位、视觉诱发电位、听觉诱发电位和听觉脑干诱发电位)的方法。提出了一种分析异常多模态诱发电位(分级诱发性脑损伤电位)的方法,该方法可确定电生理数据的异常程度,并以每种模态简单地分为四个等级来表示。给出了20名正常受试者的数据,以便与51名颅脑外伤患者获得的异常数据进行比较。