Suppr超能文献

使用3M微血管耦合装置进行下肢静脉吻合的显微外科重建。

Microsurgical reconstruction of the lower extremity using the 3M microvascular coupling device in venous anastomoses.

作者信息

Denk M J, Longaker M T, Basner A L, Glat P M, Karp N S, Kasabian A K

机构信息

Institute of Reconstructive Plastic Surgery, New York University Medical Center, NY, USA.

出版信息

Ann Plast Surg. 1995 Dec;35(6):601-6. doi: 10.1097/00000637-199512000-00008.

Abstract

Microsurgical reconstruction of the lower extremity presents a difficult problem to plastic surgeons; the rate of failure is higher than any other anatomical site. We reviewed our recent experience with lower extremity microsurgical reconstruction using the 3M vascular coupling device. We believe the excellent patency rate of the coupler may minimize the well-described problem of venous thrombosis in this challenging group of patients. This study involves a consecutive series of 11 patients who presented for reconstructive microsurgery of the lower extremity at NYU Medical Center hospitals between June 1 and September 1, 1994. Ten of 11 patients had free flap transfer to traumatic lower extremity injuries, whereas the remaining reconstruction was in a diabetic individual with a chronic wound. Fifteen microvascular venous anastomoses were performed; all but 1 was performed using the 3M coupler. Our experience with 11 patients, involving 14 mechanically coupled venous anastomoses, demonstrated successful use of the coupler. No intraoperative or postoperative vascular complications occurred. The overall success rate of the 3M coupler for venous anastomoses was 100%, and all microvascular free flaps were successful. We recommend using the 3M coupling device for venous anastomoses during reconstructive microsurgery of the lower extremity. Our series demonstrates the safety and effectiveness of the 3M coupler in this challenging group of patients. In addition, a secondary benefit of the 3M coupler is a significant reduction in operative time.

摘要

下肢的显微外科重建给整形外科医生带来了难题;其失败率高于其他任何解剖部位。我们回顾了近期使用3M血管连接装置进行下肢显微外科重建的经验。我们认为,在这群具有挑战性的患者中,连接装置出色的通畅率可能会将静脉血栓形成这一广为人知的问题降至最低。本研究纳入了1994年6月1日至9月1日期间在纽约大学医学中心各医院接受下肢重建显微外科手术的11例连续患者。11例患者中有10例进行了游离皮瓣移植以修复下肢创伤,其余1例为患有慢性伤口的糖尿病患者。共进行了15次微血管静脉吻合;除1次外,其余均使用3M连接装置完成。我们对11例患者(涉及14次机械连接的静脉吻合)的经验表明,该连接装置使用成功。未发生术中或术后血管并发症。3M连接装置用于静脉吻合的总体成功率为100%,所有游离微血管皮瓣均成功。我们建议在下肢重建显微外科手术中使用3M连接装置进行静脉吻合。我们的系列研究证明了3M连接装置在这群具有挑战性的患者中的安全性和有效性。此外,3M连接装置的另一个好处是显著缩短了手术时间。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验