Döler W, Fischer U, Metzger I, Harder D, Grabbe E
Institute of Medical Physics and Biophysics, Georg-August-Universität Göttingen, Germany.
Radiology. 1996 Sep;200(3):863-4. doi: 10.1148/radiology.200.3.8756945.
Breast biopsy and lesion localization were performed with gadolinium-enhanced magnetic resonance (MR) imaging guidance, with use of a stereotaxic biopsy system consisting of a flexible circular surface coil with an acrylic cylinder as an add-on guidance device. Twenty-five procedures (23 localizations, two core biopsies) were performed in lesions depicted at diagnostic MR imaging, without technical failure. The guidance system permitted easy, precise, and flexible biopsy and localization of all breast lesions.
在钆增强磁共振(MR)成像引导下进行乳房活检和病变定位,使用由带有丙烯酸圆柱体作为附加引导装置的柔性圆形表面线圈组成的立体定位活检系统。在诊断性MR成像显示的病变中进行了25次操作(23次定位,2次粗针活检),无技术故障。该引导系统允许对所有乳腺病变进行轻松、精确和灵活的活检及定位。