Suppr超能文献

Validity and reliability of spinal cord monitoring in neuromuscular spinal deformity surgery.

作者信息

Padberg A M, Russo M H, Lenke L G, Bridwell K H, Komanetsky R M

机构信息

Department of Orthopaedic Surgery, Washington University Medical Center, St. Louis, Missouri, USA.

出版信息

J Spinal Disord. 1996 Apr;9(2):150-8.

PMID:8793784
Abstract

Somatosensory evoked potentials (SSEPs) have become a standard of care in surgery for spinal deformity. Recent reports in the literature have suggested SSEP monitoring is not efficacious in surgeries for patients with neuromuscular disease. Electrophysiologic data were retrospectively analyzed from 74 patients with various neuromuscular disorders undergoing spinal-deformity surgery from 1989 through February 1995 at this medical center. The monitoring protocol included SSEPs recorded from multiple sites located cortically, subcortically, and peripherally. Neurogenic motor evoked potentials (NMEPs) were also employed. Anesthetic regimens were controlled for compatibility with evoked potential monitoring. Use of this intraoperative monitoring protocol resulted in reliable data for 95% of the patient population having baseline responses. Findings suggest that evoked potentials can be used effectively during surgery for neuromuscular spinal deformity. Use of a specific protocol allowed acquisition of reliable data intraoperatively, suggesting these methods are a valid means of monitoring neurologic status.