Analytical description of the high and low contrast behavior of a scan-rotate geometry for equalization mammography.

作者信息

Sabol J M, Plewes D B

机构信息

Department of Medical Biophysics and Imaging Research, Sunnybrook Health Science Centre University of Toronto, Ontario, Canada.

出版信息

Med Phys. 1996 Jun;23(6):887-98. doi: 10.1118/1.597731.

DOI:10.1118/1.597731
PMID:8798174
Abstract

Many solutions have been proposed to overcome the problem of imaging the radiographically dense breast with high contrast mammographic film of limited dynamic range. In previous works, we have proposed utilizing a modulated fan-beam in a scan-rotate geometry RSER (Rotary Scanning Equalization Radiography), as an efficient method for producing exposure equalized mammograms. The image quality of RSER is similar to that attained with the inefficient single beam, raster scanning SER (Scanning Equalization Radiography) geometry. RSER has the potential to be a practical, efficient method for improving the detection of cancer in the dense breast. In this work, we present a theoretical analysis of the imaging properties of the RSER geometry in two regimes defined by the variation of x-ray transmission within the object. For low contrast objects, the imaging geometry was analyzed as a linear system, whereas the high contrast regime was studied by determining the contrast limit at which RSER requires nonphysical (negative) exposure modulation for a breast-like object. The low contrast transfer function of the RSER system is shown to be very similar to that of the SER geometry. We show that RSER enables the use of wide scanning beam of approximately 4 cm and thereby significantly reduces x-ray tube heat loading. Analysis of the high contrast behavior shows that a wide range of object contrasts and sizes can be equalized. For example, RSER can equalize a region of 100% glandular tissue within a 4.0 cm thick compressed breast composed of 100% adipose tissue. Thus, the RSER geometry produces images very similar to the more inefficient SER geometry, and is able to produce entrance exposure distributions appropriate for equalization of the range of contrast typically encountered in mammography.

摘要

相似文献

1
Analytical description of the high and low contrast behavior of a scan-rotate geometry for equalization mammography.
Med Phys. 1996 Jun;23(6):887-98. doi: 10.1118/1.597731.
2
Practical application of a scan-rotate equalization geometry to mammography.扫描-旋转均衡几何在乳腺摄影中的实际应用。
Med Phys. 1996 Dec;23(12):1987-96. doi: 10.1118/1.597770.
3
A method for practical equalization mammography of the radiographically dense breast.
Radiographics. 1995 Sep;15(5):1191-202. doi: 10.1148/radiographics.15.5.7501859.
4
Rotary scanning equalization radiography: an efficient geometry for equalization mammography.旋转扫描均衡放射摄影术:一种用于均衡乳腺摄影的有效成像方式
Med Phys. 1994 Oct;21(10):1523-33. doi: 10.1118/1.597262.
5
Mammographic scanning equalization radiography.
Med Phys. 1993 Sep-Oct;20(5):1505-15. doi: 10.1118/1.597114.
6
Observer performance and dose efficiency of mammographic scanning equalization radiography.
Med Phys. 1993 Sep-Oct;20(5):1517-25. doi: 10.1118/1.597115.
7
Cone-beam volume CT breast imaging: feasibility study.锥形束容积CT乳腺成像:可行性研究。
Med Phys. 2002 May;29(5):755-70. doi: 10.1118/1.1461843.
8
Analytical optimization of digital subtraction mammography with contrast medium using a commercial unit.使用商用设备对造影剂增强数字化乳腺摄影进行分析优化。
Med Phys. 2008 Dec;35(12):5544-57. doi: 10.1118/1.3003063.
9
AEC for scanning digital mammography based on variation of scan velocity.基于扫描速度变化的数字乳腺摄影扫描自动曝光控制
Med Phys. 2005 Nov;32(11):3367-74. doi: 10.1118/1.2089487.
10
Technique factors and their relationship to radiation dose in pendant geometry breast CT.悬垂式乳腺CT中的技术因素及其与辐射剂量的关系
Med Phys. 2005 Dec;32(12):3767-76. doi: 10.1118/1.2128126.

引用本文的文献

1
Effects of exposure equalization on image signal-to-noise ratios in digital mammography: a simulation study with an anthropomorphic breast phantom.曝光均衡对数字乳腺摄影图像信噪比的影响:用人形乳房体模进行的模拟研究。
Med Phys. 2011 Dec;38(12):6489-501. doi: 10.1118/1.3659709.
2
Model-based technique for the measurement of skin thickness in mammography.基于模型的乳腺钼靶摄影中皮肤厚度测量技术
Med Biol Eng Comput. 2002 Mar;40(2):153-62. doi: 10.1007/BF02348119.