• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Intravascular oxygenation. Influence of the host vessel diameter on oxygen transfer.

作者信息

von Segesser L K, Tönz M, Mihaljevic T, Marty B, Leskosek B, Turina M

机构信息

Clinic for Cardiovascular Surgery, University Hospital, Lausanne, Switzerland.

出版信息

ASAIO J. 1996 Jul-Aug;42(4):246-9.

PMID:8828778
Abstract

An extra corporeal venovenous bypass circuit (right atrium to pulmonary artery), including an intravascular gas exchanger in a blood chamber with a variable inner diameter, was developed for ex vivo evaluation of the host vessel diameter/intravascular oxygen transfer relationship. Three host vessel diameters mimicking different configurations of the caval axis were studied in three bovine experiments (body weight 82 +/- 3 kg). Blood flow was 3,000 ml/min and device oxygen inflow was 2,300 ml/min. Serial blood samples were taken for 26 mm, 23 mm, and 20 mm inner blood chamber diameters after hemodynamic stabilization before and after exposure of the circulating blood to the intravascular gas exchanger (sampling ports at blood chamber inlet and outlet). Measured oxygen saturation at the blood chamber inlet was 25.0 +/- 11.7% for the 26 mm diameter as compared to 31.7 +/- 12.6% for 23 mm, and 28.7 +/- 9.2% for 20 mm. At the outlet, the corresponding O2 saturations were 34.5 +/- 11.5% for 26 mm, 42.9 +/- 8.8% for 23 mm, and 43.2 +/- 6.2 for 20 mm. Total O2 transfer was 24.9 +/- 11.5 ml/min for 26 mm, 31.9 +/- 7.4 ml/min for 23 mm, and 35.9 +/- 12.2 ml/min for 20 mm (p < 0.05). Likewise, O2 transfer rate was 8.3 +/- 3.8 ml/L, 10.6 +/- 2.4 ml/L, and 12.0 +/- 4.0 ml/L (p < 0.05). Parallel analyses of total CO2 transfer and CO2 transfer rates provided less consistent findings. At 3 L/min, the pressure drop between the inlet and outlet of the blood chamber was 12 +/- 3 mmHg for 26 mm, 26 +/- 1 mmHg for 23 mm, and 38 +/- 2 mmHg for 20 mm diameters (p < 0.001). The authors conclude that oxygen transfer of a given intravascular gas exchanger appears to be indirectly proportional to the host vessel diameter. Increasing blood pressure gradient as a function of decreasing diameter has to be considered in clinical application.

摘要

相似文献

1
Intravascular oxygenation. Influence of the host vessel diameter on oxygen transfer.
ASAIO J. 1996 Jul-Aug;42(4):246-9.
2
Intravascular gas transfer. Membrane surface area and sweeping gas flows are of prime importance.血管内气体转移。膜表面积和吹扫气流至关重要。
ASAIO J. 1997 Sep-Oct;43(5):M457-9.
3
Influence of hemodynamics on the performances of intravascular gas exchangers.
Ann Thorac Surg. 1995 Dec;60(6):1665-70. doi: 10.1016/0003-4975(95)00647-8.
4
[Hemodynamic effects of the implantation of an intracaval oxygenator].[腔静脉内氧合器植入的血流动力学效应]
Schweiz Med Wochenschr. 1993 Apr 3;123(13):600-2.
5
[Hemodynamic effects of implantation of an intracaval gas exchanger].[腔静脉内气体交换器植入的血流动力学效应]
Helv Chir Acta. 1993 Jun;59(5-6):887-92.
6
Quantitative gas transfer of an intravascular oxygenator.
Ann Thorac Surg. 1994 Jan;57(1):146-50. doi: 10.1016/0003-4975(94)90383-2.
7
[In vitro testing of the intravenacaval respiratory assist device (I)--Pressure drop characteristics and oxygen transfer performance].腔静脉内呼吸辅助装置的体外测试(I)——压降特性与氧传递性能
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 1998 Sep;15(3):218-23.
8
Coronary sinus venoarterial CO2 difference in different hemodynamic states.不同血流动力学状态下的冠状静脉窦动静脉二氧化碳差值。
Acta Anaesthesiol Belg. 2004;55(3):221-7.
9
The effects of preprimed oxygenators on gas transfer efficiency.预充氧合器对气体传输效率的影响。
J Extra Corpor Technol. 2003 Jun;35(2):121-6.
10
Use of a mathematical model to predict oxygen transfer rates in hollow fiber membrane oxygenators.使用数学模型预测中空纤维膜式氧合器中的氧传递速率。
ASAIO J. 1994 Oct-Dec;40(4):990-6.

引用本文的文献

1
Intravascular Gas Exchange: Physiology, Literature Review, and Current Efforts.血管内气体交换:生理学、文献回顾和当前研究进展。
Respir Care. 2022 Apr;67(4):480-493. doi: 10.4187/respcare.09288.