Jensen C H, Jensen C M
Department of Orthopaedics, University Hospital of Copenhagen, Hvidovre, Denmark.
J Hand Surg Br. 1996 Aug;21(4):507-10. doi: 10.1016/s0266-7681(96)80056-8.
We compared biodegradable pins with standard Kirschner wires in the fixation of fractures, arthrodeses and osteotomies in the hand in a prospective, randomized study. Eleven patients were allocated to the biodegradable pin group and 12 to the Kirschner wire group. Age, gender, operative procedure and postoperative treatment did not differ in the two groups. All patients were evaluated after 6 months. No differences in time to union or complication rates were found, but the number of additional operative procedures in the Kirschner wire group significantly exceeded the number needed in the biodegradable pin group.
在一项前瞻性随机研究中,我们对手部骨折、关节融合术和截骨术的固定,将可生物降解钢针与标准克氏针进行了比较。11名患者被分配到可生物降解钢针组,12名患者被分配到克氏针组。两组患者的年龄、性别、手术操作和术后治疗并无差异。所有患者在6个月后接受评估。在愈合时间或并发症发生率方面未发现差异,但克氏针组额外手术操作的数量显著超过可生物降解钢针组所需的数量。