Suppr超能文献

Electrophysiologic characteristics and anatomical complexities of accessory atrioventricular pathways with successful ablation of anterograde and retrograde conduction at different sites.

作者信息

Chen S A, Tai C T, Lee S H, Chiang C E, Wen Z C, Chiou C W, Ueng K C, Chen Y J, Yu W J, Huang J L, Chang M S

机构信息

Department of Medicine, National Yang-Ming University, Taiwan, Republic of China.

出版信息

J Cardiovasc Electrophysiol. 1996 Oct;7(10):907-15. doi: 10.1111/j.1540-8167.1996.tb00465.x.

Abstract

INTRODUCTION

Catheter ablation may eliminate anterograde and retrograde accessory pathway conduction at closely adjacent but anatomically discrete sites. However, the mechanisms of this discrepancy, the electrophysiologic and anatomical characteristics, and information about systematic study from a large patient population are not available. The purpose of this study was to investigate the electrophysiologic characteristics and anatomical complexities of the accessory pathway in which anterograde and retrograde conduction was successfully ablated at different sites.

METHODS AND RESULTS

Thirty-eight (10.9%) patients (19 men and 19 women; mean age 37 +/- 2.4 years) fulfilling the criteria of having separate ablation sites for anterograde and retrograde conduction were designated as group I, and the other 310 patients (215 men and 95 women; mean age 47 +/- 0.6 years) were designated as group II. The patients with right-sided free-wall pathways had the highest incidence (18.6%) of separate ablation sites. The anatomical distance between anterograde and retrograde directions (left anterior oblique view, 13 +/- 0.6 vs 8 +/- 0.9 mm, P < 0.01; right anterior oblique view, 17 +/- 0.6 vs 5 +/- 0.7 mm, P < 0.01), and incidence of conduction impairment in one direction after successful ablation of another direction (15% vs 78%, P < 0.05) differed significantly between left and right free-wall pathways. The mean distances obtained from left (7 +/- 0.4 vs 14 +/- 0.4 mm, P < 0.05) and right (7 +/- 1.1 vs 15 +/- 0.9 mm, P < 0.05) anterior oblique views were shorter in patients who had impairment of conduction properties than those in patients without impaired conduction after successful ablation of one direction.

CONCLUSIONS

This study showed that anatomical and functional dissociation of the accessory pathway into anterograde and retrograde components was possible. Further study on the relation between electrophysiologic and pathologic characteristics would be helpful to confirm these findings.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验