Suppr超能文献

Electrophysiologic characteristics and anatomical complexities of accessory atrioventricular pathways with successful ablation of anterograde and retrograde conduction at different sites.

作者信息

Chen S A, Tai C T, Lee S H, Chiang C E, Wen Z C, Chiou C W, Ueng K C, Chen Y J, Yu W J, Huang J L, Chang M S

机构信息

Department of Medicine, National Yang-Ming University, Taiwan, Republic of China.

出版信息

J Cardiovasc Electrophysiol. 1996 Oct;7(10):907-15. doi: 10.1111/j.1540-8167.1996.tb00465.x.

Abstract

INTRODUCTION

Catheter ablation may eliminate anterograde and retrograde accessory pathway conduction at closely adjacent but anatomically discrete sites. However, the mechanisms of this discrepancy, the electrophysiologic and anatomical characteristics, and information about systematic study from a large patient population are not available. The purpose of this study was to investigate the electrophysiologic characteristics and anatomical complexities of the accessory pathway in which anterograde and retrograde conduction was successfully ablated at different sites.

METHODS AND RESULTS

Thirty-eight (10.9%) patients (19 men and 19 women; mean age 37 +/- 2.4 years) fulfilling the criteria of having separate ablation sites for anterograde and retrograde conduction were designated as group I, and the other 310 patients (215 men and 95 women; mean age 47 +/- 0.6 years) were designated as group II. The patients with right-sided free-wall pathways had the highest incidence (18.6%) of separate ablation sites. The anatomical distance between anterograde and retrograde directions (left anterior oblique view, 13 +/- 0.6 vs 8 +/- 0.9 mm, P < 0.01; right anterior oblique view, 17 +/- 0.6 vs 5 +/- 0.7 mm, P < 0.01), and incidence of conduction impairment in one direction after successful ablation of another direction (15% vs 78%, P < 0.05) differed significantly between left and right free-wall pathways. The mean distances obtained from left (7 +/- 0.4 vs 14 +/- 0.4 mm, P < 0.05) and right (7 +/- 1.1 vs 15 +/- 0.9 mm, P < 0.05) anterior oblique views were shorter in patients who had impairment of conduction properties than those in patients without impaired conduction after successful ablation of one direction.

CONCLUSIONS

This study showed that anatomical and functional dissociation of the accessory pathway into anterograde and retrograde components was possible. Further study on the relation between electrophysiologic and pathologic characteristics would be helpful to confirm these findings.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验