Iwasaki T, Ojima J
National Institute of Industrial Health, Kawasaki, Japan.
Ind Health. 1996;34(4):389-401. doi: 10.2486/indhealth.34.389.
In the ductwork of local exhaust systems, 90 degrees elbow pipes (JIS K 6739) are commonly used to alter the direction of airflow; thus, are important components of polyvinyl chloride (PVC) ducts. Pressure loss in 90 degrees PVC elbow pipes was investigated by measuring static pressure, and the characteristics of airflow was determined. First, a linear decrease in static pressure was observed at points of the downstream side beyond a distance of 10 times the diameter (10d) from the flanged round opening of the smooth VU ducts (JIS K6741). The linear decrease was also observed at points of the downstream side located at distances of greater than 30d from the elbow pipe. Coefficients of loss in the PVC elbow pipes were found to be constant for the Reynolds numbers ranging from 3.38 x 10(4) to 5.96 x 10(5) for all diameters examined, and a chart of pressure loss was constructed with these coefficients. The coefficients of loss in PVC elbow pipes were not equivalent to those of metal stamped elbows for any R/d. However, the differences in the coefficients between the metal stamped elbow and the PVC elbow were smaller with larger R/d values.
在局部排风系统的风道中,90度弯头管(JIS K 6739)常用于改变气流方向,因此是聚氯乙烯(PVC)风道的重要组成部分。通过测量静压研究了90度PVC弯头管中的压力损失,并确定了气流特性。首先,在光滑VU风道(JIS K6741)法兰圆形开口下游超过管径10倍(10d)距离的点处,观察到静压呈线性下降。在距弯头管大于30d距离的下游侧点处也观察到线性下降。对于所有检查的管径,发现PVC弯头管的损失系数在雷诺数范围为3.38×10⁴至5.96×10⁵时保持恒定,并根据这些系数绘制了压力损失图表。对于任何R/d,PVC弯头管的损失系数都不等于金属冲压弯头的损失系数。然而,金属冲压弯头和PVC弯头之间的系数差异在R/d值较大时较小。