• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Slurry preparation by high-pressure homogenization for the determination of heavy metals in zoological and botanical certified reference materials and animal feeds by electrothermal atomic absorption spectrometry.

作者信息

Tan Y, Blais J S, Marshall W D

机构信息

Department of Food Science and Agricultural Chemistry, Macdonald Campus of McGill, Ste.-Anne-de-Bellevue, Québec, Canada.

出版信息

Analyst. 1996 Oct;121(10):1419-24. doi: 10.1039/an9962101419.

DOI:10.1039/an9962101419
PMID:8918215
Abstract

High-pressure homogenization was evaluated for the preparation of slurries suitable for the determination by ETAAS of Cr, Cu, Fe, Mn, Ni and Se in soft organ tissues (liver and kidney), certified reference materials of biological and botanical origin and animal feeds. Frozen fresh organ tissue, (2 g) or certified reference material or dried, ground plant material (0.1 g) was blended, at high speed with 20 ml of ethanol-water (1 + 9 v/v) containing 0.25% m/m of tetramethylammonium hydroxide and the resulting mixture was subjected to homogenization at 38.9 MPa. After four passes through the homogenizer, the resulting solution was suitable for analysis by ETAAS. Capping the flat valve head of the homogenizer with a ruby disc appreciably reduced (but did not eliminate) metal contamination introduced by the processing. Homogenization of botanical reference materials or dried animal feeds resulted in preparations with variable amounts of residual fibres and particulate matter in the resulting suspensions. Nonetheless, all the Cu and Mn and virtually all of the Fe had been transferred to the supernatant fraction and remained with that fraction for at least 10 d. The addition of EDTA to the solvent modestly increased the mobilization of Fe from the matrix but also increased the contamination from the homogenizer. The slopes of the calibration curves generated by the method of standard additions were not significantly different from those of calibration curves generated with aqueous standards in a homogenized blank indicating that there was no significant matrix effect for any of the analytes in the nine reference materials, liver or kidney or the five animal feed samples and that aqueous standards could be used to calibrate the instrumental response.

摘要

相似文献

1
Slurry preparation by high-pressure homogenization for the determination of heavy metals in zoological and botanical certified reference materials and animal feeds by electrothermal atomic absorption spectrometry.
Analyst. 1996 Oct;121(10):1419-24. doi: 10.1039/an9962101419.
2
Slurry preparation by high-pressure homogenization for cadmium, copper and lead determination in cervine liver and kidney by electrothermal atomic absorption spectrometry.
Analyst. 1996 Apr;121(4):483-8. doi: 10.1039/an9962100483.
3
Enzymatic digestion-high-pressure homogenization prior to slurry introduction graphite furnace atomic absorption spectrometry for selenium determination in plant and animal tissues.在将样品引入石墨炉原子吸收光谱仪之前,采用酶消化-高压均质法测定动植物组织中的硒。
J Agric Food Chem. 1999 Sep;47(9):3727-32. doi: 10.1021/jf981218w.
4
Determination of selenium in marine biological tissues by transverse heated electrothermal atomic absorption spectrometry with longitudinal Zeeman background correction and automated ultrasonic slurry sampling.采用纵向塞曼背景校正横向加热电热原子吸收光谱法及自动超声悬浮进样技术测定海洋生物组织中的硒。
J AOAC Int. 2001 Nov-Dec;84(6):1921-6.
5
Determination of zinc in tissues of normal and dystrophic mice using electrothermal atomic absorption spectrometry and slurry sampling.用电热原子吸收光谱法和悬浮液进样法测定正常和营养不良小鼠组织中的锌
Anal Biochem. 2006 Jan 1;348(1):64-8. doi: 10.1016/j.ab.2005.10.017. Epub 2005 Oct 27.
6
Slurry sampling graphite furnace atomic absorption spectrometry: determination of trace metals in mineral coal.悬浮液进样石墨炉原子吸收光谱法:测定动力煤中的痕量金属
Talanta. 1999 Dec 6;50(5):1035-43. doi: 10.1016/s0039-9140(99)00216-7.
7
Comparative determination of Ba, Cu, Fe, Pb and Zn in tea leaves by slurry sampling electrothermal atomic absorption and liquid sampling inductively coupled plasma atomic emission spectrometry.浆体取样电热原子吸收法和液体取样电感耦合等离子体原子发射光谱法比较测定茶叶中的钡、铜、铁、铅和锌。
Talanta. 1998 Dec;47(5):1263-70. doi: 10.1016/s0039-9140(98)00214-8.
8
Evaluation of microwave digestion and solvent extraction for the determination of trace amounts of selenium in feeds and plant and animal tissues by electrothermal atomic absorption spectrometry.通过电热原子吸收光谱法评估微波消解和溶剂萃取法测定饲料、植物和动物组织中痕量硒的效果。
Analyst. 1991 May;116(5):505-9. doi: 10.1039/an9911600505.
9
Determination of copper, cobalt, nickel, and manganese in baby food slurries using electrothermal atomic absorption spectrometry.
J Agric Food Chem. 2000 Dec;48(12):5789-94. doi: 10.1021/jf000479e.
10
Mineral content in legumes and nuts: contribution to the Spanish dietary intake.豆类和坚果中的矿物质含量:对西班牙人饮食摄入量的贡献。
Sci Total Environ. 2003 Jun 1;308(1-3):1-14. doi: 10.1016/S0048-9697(02)00611-3.