Kolinko A I, Zelikson B B
Fiziol Zh SSSR Im I M Sechenova. 1977 Jul;63(7):970-5.
In cats, the rheogram of a portion of the vascular tract was recorded during changes of the eye pressure due to brief increase or decrease of the central arterial pressue. Comparison of the recorded changes with the oscillations of electrical conductivity suggest that the latter reflect primarily the changes of the blood linear speed during the time of one pulse cycle (at frequencies over 30 kHz). Slow changes of the electrical conductivity as recorded during electroplethysmography of the vascular tract, reflect primarily the changes of blood volume in the eye tunics.
在猫身上,当中心动脉压短暂升高或降低导致眼压变化时,记录了部分血管通路的血流图。将记录的变化与电导率振荡进行比较表明,后者主要反映一个脉搏周期内(频率超过30kHz时)血液线速度的变化。在血管通路的电阻抗容积描记术中记录到的电导率缓慢变化,主要反映眼组织中血容量的变化。