[Evaluation of simultaneous acquisition of transmission and emission data on thallium-201 myocardial SPECT].

作者信息

Tomiguchi S, Oyama Y, Kira T, Kira M, Nakashima R, Tsuji A, Kojima A, Matsumoto M, Takahashi M, Inobe Y, Yasue H

机构信息

Department of Radiology, Kumamoto University Medical School.

出版信息

Kaku Igaku. 1996 Sep;33(9):1027-35.

PMID:8921673
Abstract

This study evaluates the usefulness of attenuation correction on regional myocardial tracer distributions defined by Thallium-201 myocardial SPECT images obtained from cardiac phantoms and patients with or without coronary heart disease. A three-detector SPECT system equipped with a Technetium-99m line source and a fan-beam collimator was used for simultaneous transmission and emission data acquisition. All three detectors were equipped with fan-beam collimators. Thallium-201 myocardial scintigraphy was performed on phantom study and 19 patients. Transmission images, uncorrected and corrected emission images were iteratively reconstructed with a EM-ML algorithm. Attenuation map computed from the transmission data was utilized for the attenuation correction. For the phantom study, circumferential profile analysis was applied to both datasets of horizontal long-axis slices through the center of the phantom. The maximum profile value in the circumferential profile set to 100% in the normalized uncorrected and corrected profiles. The uncorrected circumferential profiles from cardiac insert model 7070 and RH-2 cardiophantom showed decrease in activity in basal regions which appeared improvement in the attenuation corrected profiles. In clinical study, the inferior-to-anterior activity ratio, changed from 0.78 +/- 0.10 to 0.97 +/- 0.11 on stress images in patients with inferior ischemia and from 0.96 +/- 0.12 to 1.15 +/- 0.13 on 4 hour delayed or rest images in normal cases. The anteroapical wall of the attenuation corrected images, however, showed a decrease in activity relative to the inferior wall in normal cases. The increase in activity in inferior wall on attenuation corrected images was observed frequently in clinical study but not in phantom study. A presence of scatter from the liver or bowels may cause the increase in activity in the inferior wall in clinical study. In conclusion, transmission scan is one of the useful methods for the attenuation correction. Scatter correction, however, is also necessary to make an accurate attenuation corrected images.

摘要

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验