• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Measurement of surgically induced corneal deformations using three-dimensional confocal microscopy.

作者信息

Petroll W M, Roy P, Chuong C J, Hall B, Cavanagh H D, Jester J V

机构信息

Department of Ophthalmology, University of Texas, Southwestern Medical Center, Dallas 75235-9057, USA.

出版信息

Cornea. 1996 Mar;15(2):154-64. doi: 10.1097/00003226-199603000-00008.

DOI:10.1097/00003226-199603000-00008
PMID:8925663
Abstract

The goal of this study was to develop and apply a new set of experimental techniques for measuring the local deformations induced by partial-thickness corneal incisions in situ. Eight adult cat eyes were enucleated and cannulated, with corneal viability maintained as close to in vivo conditions as possible and intraocular pressure (IOP) carefully controlled. Experimental measurements were made pre/post radial keratotomy (RK) surgery in situ at IOPs of 15, 30, and 45 mm Hg. Incision depth and cross-sectional profiles were measured at the midpoint of selected incisions using three-dimensional (3-D) tandem scanning confocal microscopy (TSCM); central corneal curvature was estimated using a commercial corneal topographical analysis system, and corneal thickness was assessed by both 3-D TSCM and ultrasonic pachymetry. Corneas were then processed for light microscopy and incision depth was measured histologically. Finite element models were developed for comparison with the experimental measurements. There was no significant change in central corneal thickness (-5.3 +/- 3.9%, n = 8) over the course of the experiments, demonstrating that normal endothelial cell function and normal stromal hydration was maintained. The in situ TSCM incision depth measurements were significantly correlated with the histological measurements (slope = 0.95, R = 0.854, p < 0.01, n = 13 incisions). Measured incision gape at the top (anterior) of the stroma was 64.9 +/- 13.4, 87.3 +/- 12.6, and 108.7 +/- 14 microns at IOPs of 15, 30, and 45 mm Hg, respectively. The 3-D incision profiles were nonlinear in shape; comparison with the finite element models suggests that the shape of the wound profile may provide unique information regarding the shear stiffness of the cornea. Overall, the data suggest that TSCM measurements of the cross-sectional profile of the incisions immediately after RK under controlled in situ conditions provide important data regarding the mechanical behavior of the cornea after refractive surgery. These data should provide the foundation for future studies into the relationships between local tissue mechanics and corneal wound healing.

摘要

相似文献

1
Measurement of surgically induced corneal deformations using three-dimensional confocal microscopy.
Cornea. 1996 Mar;15(2):154-64. doi: 10.1097/00003226-199603000-00008.
2
Radial keratotomy. III. Relationship between wound gape and corneal curvature in primate eyes.放射状角膜切开术。III. 灵长类动物眼睛伤口裂开与角膜曲率的关系。
Invest Ophthalmol Vis Sci. 1992 Nov;33(12):3283-91.
3
Radial keratotomy. 1. The wound healing process and measurement of incisional gape in two animal models using in vivo confocal microscopy.放射状角膜切开术。1. 使用体内共聚焦显微镜在两种动物模型中观察伤口愈合过程及测量切口间隙
Invest Ophthalmol Vis Sci. 1992 Nov;33(12):3255-70.
4
Acute tissue deformation of the human cornea after radial keratotomy.
J Refract Surg. 1996 Mar-Apr;12(3):391-400. doi: 10.3928/1081-597X-19960301-14.
5
Biomechanical behavior of the cornea and its response to radial keratotomy.角膜的生物力学行为及其对放射状角膜切开术的反应。
J Refract Corneal Surg. 1994 May-Jun;10(3):343-51; discussion 351-6.
6
Corneal thickness variation during eight-incision radial keratotomy.
J Cataract Refract Surg. 1997 May;23(4):509-14. doi: 10.1016/s0886-3350(97)80207-6.
7
Assessment of stress fiber orientation during healing of radial keratotomy wounds using confocal microscopy.使用共聚焦显微镜评估放射状角膜切开术伤口愈合过程中应力纤维的方向。
Scanning. 1998 Mar;20(2):74-82. doi: 10.1002/sca.1998.4950200202.
8
Corneal tensile strength in fully healed radial keratotomy wounds.完全愈合的放射状角膜切开术伤口的角膜抗张强度。
Invest Ophthalmol Vis Sci. 1994 Jun;35(7):3022-31.
9
Variability in corneal thickness before, during, and after radial keratotomy.放射状角膜切开术术前、术中及术后角膜厚度的变异性。
J Refract Surg. 1996 Sep-Oct;12(6):700-4. doi: 10.3928/1081-597X-19960901-12.
10
Pharmacologic alteration of corneal topography after radial keratotomy.
Ophthalmic Surg. 1992 Nov;23(11):738-41.

引用本文的文献

1
Long-term changes in keratometry and refraction after small aperture corneal inlay implantation.小孔径角膜嵌体植入术后角膜曲率计和屈光的长期变化
Clin Ophthalmol. 2018 Oct 4;12:1931-1938. doi: 10.2147/OPTH.S164964. eCollection 2018.
2
Evaluation of corneal thickness and topography in normal eyes using the Orbscan corneal topography system.使用Orbscan角膜地形图系统评估正常眼睛的角膜厚度和地形图。
Br J Ophthalmol. 1999 Jul;83(7):774-8. doi: 10.1136/bjo.83.7.774.