Suppr超能文献

[静脉注射胺碘酮对缺血性心脏病患者心室信号平均心电图维持的影响]

[The effect of intravenously given amiodarone on maintenance of ventricular signal averaged electrocardiogram in patients with ischemic heart disease].

作者信息

Banasiak W, Pieróg M, Kokot K, Fuglewicz A, Zapałowicz R, Telichowski A, Lacheta W, Molenda W, Góral J, Fudalej L, Pajak I, Telichowski C

机构信息

Kliniki Chorób Wewnetrznych Wojskowego Szpitala Klinicznego, Wrocławiu.

出版信息

Przegl Lek. 1996;53(6):463-7.

PMID:8927746
Abstract

Recording of ventricular signal-averaged ECG (VSAE) were carried out in 19 patients suffering from ischemic heart disease before and after intravenously administration of amiodarone using a commercially available machine HIPEC-200 HA device of Aerotel's. The high gain ECG was recorded during basic rhythm with orthogonal Frank leads X, Y, Z. These combined into a vector magnitude and the QRS duration (QRS), the duration of low amplitude signals < 40 microV (LPD) and the root mean square voltage of the signals in the last 40 and 50 ms of the filtered QRS (RMS 40,50) were calculated for VSAE. It was time-domain analysis of VSAE. In frequency domain analysis were calculated the following parameters in range from 40 Hz to 400 Hz in linear scale: area ratio 20-50 Hz/0-20 Hz, peak and magnitude ratio and in logarithmic scale: energy spectrum > -60 dB and decibel drop at 40 Hz. Subsequently amiodarone hydrochloride was given intravenously 5 mg/kg c.c. and again time-domain and frequency domain analysis were done. Data presented are mean +/- standard deviation. Statistical comparisons were performed with paired t-Student test. Significance refers to a p values < 0.05. Time-domain analysis of VSAE didn't show any significant differences after amiodarone injection. During frequency-domain analysis of VSAE statistically significant differences were displayed in Frank lead X and Y for energy spectrum > -60 dB. In Frank lead X decrease of this parameter after amiodarone (from 3322 +/- 1057 dB-Hz to 2628 +/- 733) and in lead Y increase (from 2793 +/- 500 dB-Hz to 3199 +/-938 dB-Hz) was noticed. Our observation have indicated that intravenously application of amiodarone hydrochloride didn't change parameters in time-domain analysis. Statistically significant differences were noticed only during frequency analysis VSAE in logarithmic scale -energy spectrum > -60 dB but only in two leads X and Y.

摘要

对19例缺血性心脏病患者,使用Aerotel公司的市售HIPEC - 200 HA设备,在静脉注射胺碘酮前后进行心室信号平均心电图(VSAE)记录。在基础心律下,用正交Frank导联X、Y、Z记录高增益心电图。将这些导联组合成一个向量幅值,并计算VSAE的QRS波持续时间(QRS)、低幅信号<40微伏的持续时间(LPD)以及滤波后QRS波最后40和50毫秒内信号的均方根电压(RMS 40,50)。这是VSAE的时域分析。在频域分析中,在线性尺度下计算40赫兹至400赫兹范围内的以下参数:20 - 50赫兹/0 - 20赫兹的面积比、峰值和幅值比,在对数尺度下计算:能量谱>-60分贝和40赫兹处的分贝下降。随后静脉注射盐酸胺碘酮5毫克/千克体重,再次进行时域和频域分析。给出的数据为平均值±标准差。采用配对t检验进行统计学比较。显著性指p值<0.05。胺碘酮注射后,VSAE的时域分析未显示任何显著差异。在VSAE的频域分析中,对于能量谱>-60分贝,Frank导联X和Y显示出统计学显著差异。在Frank导联X中,胺碘酮注射后该参数下降(从3322±1057分贝 - 赫兹降至2628±733),在导联Y中升高(从2793±500分贝 - 赫兹升至3199±938)。我们的观察表明,静脉应用盐酸胺碘酮在时域分析中未改变参数。仅在VSAE的对数尺度频域分析中,即能量谱>-60分贝时,仅在两个导联X和Y中发现统计学显著差异。

相似文献

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验