Ignatiev E A, Romanyukha A A, Koshta A A, Wieser A
EPR Spectroscopy Center, Russian Academy of Sciences, Ekaterinburg.
Appl Radiat Isot. 1996 Mar;47(3):333-7. doi: 10.1016/0969-8043(95)00293-6.
The method of selective saturation proposed is based on the difference in the microwave (mw) power dependence of the background and radiation induced EPR components of the tooth enamel spectrum. The subtraction of the EPR spectrum recorded at low mw power from that recorded at higher mw power provides a considerable reduction of the background component in the spectrum. The resolution of the EPR spectrum could be improved 10-fold, however simultaneously the signal-to-noise ratio was found to be reduced twice. A detailed comparative study of reference samples with known absorbed doses was performed to demonstrate the advantage of the method. The application of the selective saturation method for EPR dosimetry with tooth enamel reduced the lower limit of EPR dosimetry to about 100 mGy.
所提出的选择性饱和方法基于牙釉质光谱的背景和辐射诱导的电子顺磁共振(EPR)成分对微波(mw)功率依赖性的差异。从较高微波功率下记录的EPR光谱中减去在低微波功率下记录的EPR光谱,可使光谱中的背景成分大幅降低。EPR光谱的分辨率可提高10倍,但同时发现信噪比降低了一半。对具有已知吸收剂量的参考样品进行了详细的对比研究,以证明该方法的优势。将选择性饱和方法应用于牙釉质的EPR剂量测定,使EPR剂量测定的下限降低到约100毫戈瑞。