In vivo absorbed dose measurements with mini-TLDs--parameters affecting the reliability.

作者信息

Strandh M, Strand S E

机构信息

Jubileumsinstitutionen, Radiation Physics Department, Lund University, Sweden.

出版信息

Acta Oncol. 1996;35(6):713-9. doi: 10.3109/02841869609084004.

Abstract

Mini-TLDs have been proposed and widely used for in vivo measurements of absorbed doses in radionuclide therapies. The present investigation reports in detail on the signal dependence on different parameters and the accuracy of this method. Rodshaped Teflon-imbedded CaSO4:Dy or LiF thermoluminescent dosimeters (TLDs) with dimensions 0.2 x 0.4 x 5 mm3 were prepared from TLD-discs. To remove paraffin from the mini-TLDs after cutting in a microtome the TLDs were Xylene-treated, which does not affect the sensitivity. Irradiated mini-TLDs are sensitive to illumination. Fading effects in darkness were examined after 60Co-irradiation at temperatures 4, 22 and 37 degrees C. For CaSO4:Dy mini-TLDs fading in air is small. The observed signal loss after implanting CaSO4:Dy mini-TLDs in gel and muscle tissue is the same at constant temperature and is increasing with the temperature. For LiF mini-TLDs the effect of signal loss in gel was smaller than for CaSO4:Dy dosimeters. For 60Co external irradiation supralinearity already starts between 0.5 and 1 Gy for both kinds of dosimeter material. There is a strong pH dependence of the signals from the mini-TLDs. For CaSO4:Dy dosimeters the loss of sensitivity in gel is smaller at higher pHs. For LiF dosimeters the loss of sensitivity is smallest for neutral pH. We conclude that using mini-TLDs for in vivo dosimetry requires careful handling and proper calibration for accuracy in the measurements. Without such calibration errors exceeding 65% for CaSO4:Dy and 40% for LiF may easily occur.

摘要

相似文献

1
In vivo absorbed dose measurements with mini-TLDs--parameters affecting the reliability.
Acta Oncol. 1996;35(6):713-9. doi: 10.3109/02841869609084004.
3
Thermoluminescent dosimeters for low dose X-ray measurements.用于低剂量X射线测量的热释光剂量计。
Appl Radiat Isot. 2016 Jan;107:340-345. doi: 10.1016/j.apradiso.2015.11.021. Epub 2015 Nov 11.
5
Production of new thermoluminescent mini-dosimeters.新型热释光微型剂量计的生产。
Phys Med Biol. 2000 Feb;45(2):479-94. doi: 10.1088/0031-9155/45/2/315.
7
A sensitivity study of micro-TLDs for in vivo dosimetry of radioimmunotherapy.
Med Phys. 1991 Nov-Dec;18(6):1195-9. doi: 10.1118/1.596750.
9
The application of CaSO4:Dy (TLD-900) to diagnostic x-ray exposures.
Med Phys. 1983 Sep-Oct;10(5):691-4. doi: 10.1118/1.595337.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验