Cavanagh P R, Ulbrecht J S, Zanine W, Welling R L, Leschinsky D, van Schie C
Center for Locomotion Studies, Penn State University, University Park 16802, USA.
Foot Ankle Int. 1996 Nov;17(11):706-8. doi: 10.1177/107110079601701111.
Experiments to determine the effects of therapeutic shoe outsole modifications frequently require the examination of many different configurations and typically use in-shoe pressure measurement to determine the optimal design. A method is presented here to allow the foot-shoe interface to remain undisturbed as different outsole designs are used in the same patient. A standard extra-depth (or super extra-depth) shoe is modified to house three receptacles for quarter-turn fasteners in a carbon fiber plate. The fasteners pass through the outsole unit and secure it firmly to the plate. Results from a typical experiment are presented to illustrate the effectiveness of the approach. It is possible that a large clinic could use this approach in complex cases to assist with optimal footwear prescription.
确定治疗性鞋外底改良效果的实验通常需要检查许多不同的配置,并且通常使用鞋内压力测量来确定最佳设计。本文介绍了一种方法,可在同一患者使用不同外底设计时,使脚与鞋的界面保持不受干扰。将标准的加厚(或超加厚)鞋进行改良,在碳纤维板中设置三个用于四分之一转紧固件的插孔。紧固件穿过外底单元并将其牢固地固定在板上。给出了一个典型实验的结果来说明该方法的有效性。大型诊所有可能在复杂病例中使用这种方法来辅助进行最佳鞋类处方。