Abstract

Methods for determining the temporal response of electroacoustic impedance instruments are presented along with sample measurements from one instrument. The conditions under which reflex artifacts may occur are discussed in light of electrical measurements of filter response characteristics and measurements of the "threshold" of the artifact measured from two subjects with no acoustic reflex.

摘要

本文介绍了确定电声阻抗仪器时间响应的方法,并给出了一台仪器的样本测量结果。根据滤波器响应特性的电学测量以及对两名无听觉反射受试者的伪迹“阈值”测量,讨论了可能出现反射伪迹的条件。