与氮-13-氨相比,发生器产生的铜-62-PTSM作为心肌正电子发射断层显像灌注示踪剂。

Generator-produced copper-62-PTSM as a myocardial PET perfusion tracer compared with nitrogen-13-ammonia.

作者信息

Tadamura E, Tamaki N, Okazawa H, Fujibayashi Y, Kudoh T, Yonekura Y, Magata Y, Nohara R, Sasayama S, Konishi J

机构信息

Department of Nuclear Medicine, Third Division, Kyoto University Faculty of Medicine, Japan.

出版信息

J Nucl Med. 1996 May;37(5):729-35.

PMID:8965135
Abstract

UNLABELLED

The purpose of this study was to determine the suitability of 62Cu-pyruvaldehyde bis(N4-methylthiosemicarbazone) (62Cu-PTSM) for estimating myocardial blood flow (MBF) over a wide range of flow by comparison with 13N-ammonia (13NH3).

METHODS

PET studies using 62Cu-PTSM and 13NH3 were performed at rest and after pharmacological vasodilatation in 9 normal subjects and 13 patients with coronary artery disease (CAD). According to the microsphere method, values for the product of the extraction fraction and MBF (ExMBF) were calculated using both tracers. In static images, the percent uptake (normalized to the peak count) of each tracer was measured in patients with CAD.

RESULTS

The myocardial tracer distribution in the normal subjects was significantly higher in the inferior wall in the 62Cu-PTSM studies and lower in the lateral wall in the 13NH3 studies. The ExMBF values showed linear correlation for both tracers in a low flow range. In a high flow range, however, the ExMBF values for 62Cu-PTSM were nonlinearly proportional to the increase of those for 13NH3 (y = 1.1 x -0.21x2, r = 0.81). The percent uptake for both tracers at baseline well correlated linearly (y = 10.4 + 0.88x, R = 0.91). After pharmacological vasodilatation underestimation of blood flow with 62Cu-PTSM was noted compared to that with 13NH3 at high flows (y = 31.8 + 0.63x, r = 0.76).

CONCLUSION

These results suggest that the MBF estimates using 62Cu-PTSM in a low flow range may be as accurate as those with 13NH3. In a high flow range, however, the extraction fraction of 62Cu-PTSM is considered to be lower than that of 13NH3, and this may limit the estimation of MBF with 62Cu-PTSM after pharmacological vasodilatation.

摘要

未标注

本研究的目的是通过与13N-氨(13NH3)比较,确定62Cu-丙酮醛双(N4-甲基硫代半卡巴腙)(62Cu-PTSM)在广泛的血流范围内评估心肌血流量(MBF)的适用性。

方法

对9名正常受试者和13名冠状动脉疾病(CAD)患者在静息状态下以及药物性血管扩张后进行了使用62Cu-PTSM和13NH3的PET研究。根据微球法,使用两种示踪剂计算提取分数与MBF的乘积(ExMBF)值。在静态图像中,测量CAD患者中每种示踪剂的摄取百分比(归一化为峰值计数)。

结果

在62Cu-PTSM研究中,正常受试者下壁的心肌示踪剂分布显著更高,而在13NH3研究中侧壁的分布更低。在低血流范围内,两种示踪剂的ExMBF值呈线性相关。然而,在高血流范围内,62Cu-PTSM的ExMBF值与13NH3的ExMBF值增加呈非线性比例关系(y = 1.1x - 0.21x2,r = 0.81)。两种示踪剂在基线时的摄取百分比呈良好的线性相关(y = 10.4 + 0.88x,R = 0.91)。在药物性血管扩张后,与13NH3相比,在高血流时发现62Cu-PTSM对血流量的低估(y = 31.8 + 0.63x,r = 0.76)。

结论

这些结果表明,在低血流范围内使用62Cu-PTSM估计MBF可能与使用13NH3一样准确。然而,在高血流范围内,62Cu-PTSM的提取分数被认为低于13NH3,这可能会限制药物性血管扩张后使用62Cu-PTSM估计MBF。