Suppr超能文献

使用一种新型单克隆抗体对乳腺癌石蜡切片中的雌激素受体进行免疫组织化学检测。

Immunohistochemical assay for oestrogen receptors in paraffin wax sections of breast carcinoma using a new monoclonal antibody.

作者信息

Huang A, Pettigrew N M, Watson P H

机构信息

Departments of Pathology, Faculty of Medicine, University of Manitoba, Winnipeg, Canada.

出版信息

J Pathol. 1996 Oct;180(2):223-7. doi: 10.1002/(SICI)1096-9896(199610)180:2<223::AID-PATH635>3.0.CO;2-H.

Abstract

The aim of this study was to evaluate the utility of a new monoclonal antibody (AER311) that targets the oestrogen receptor (ER) in an immunohistochemical assay (IHA) applied to breast cancers. Ninety-seven cases of invasive ductal carcinoma were studied by AER311-IHA using a pressure-cooking antigen retrieval technique applied to formaldehyde-fixed, paraffin-embedded tissue sections; immunostaining was assessed by semi-quantitative scoring (H score). There was 80 per cent concordance between the ER status measured by dextran-coated charcoal (DCC) assay and AER311-IHA, with 63/97 (65 per cent) tumours positive and 15/97 (15 per cent) tumours negative by both assays. Of the 12 DCC-positive cases that were negative by AER311-IHA, 11 were borderline positive (3-8 fmol/mg). Similarly, six of seven DCC-negative cases that scored positive by AER311-IHA had only borderline positive H scores (< 50). When AER311-IHA was compared with ID5-IHA, there was good concordance in ER status (77 per cent) and a significant correlation (r = 0.7, P < 0.001) between H scores. Nevertheless, the correlation between ER level determined by AER311-IHA and that measured by DCC (r = 0.53, P < 0.001) was higher than that for 1D5-IHA (r = 0.32, P = 0.002). AER311-IHA can therefore provide reliable information about the ER status of breast carcinoma on paraffin sections and is an acceptable alternative to other commercially available monoclonal antibodies.

摘要

本研究的目的是评估一种靶向雌激素受体(ER)的新型单克隆抗体(AER311)在应用于乳腺癌的免疫组织化学分析(IHA)中的效用。采用高压锅抗原修复技术,对97例浸润性导管癌的甲醛固定石蜡包埋组织切片进行AER311-IHA研究;通过半定量评分(H评分)评估免疫染色。葡聚糖包被活性炭(DCC)分析测定的ER状态与AER311-IHA之间的一致性为80%,两种分析均显示63/97(65%)的肿瘤为阳性,15/97(15%)的肿瘤为阴性。在AER311-IHA为阴性的12例DCC阳性病例中,11例为临界阳性(3-8 fmol/mg)。同样,在AER311-IHA评分为阳性的7例DCC阴性病例中,有6例H评分仅为临界阳性(<50)。当将AER311-IHA与ID5-IHA进行比较时,ER状态的一致性良好(77%),H评分之间存在显著相关性(r = 0.7,P < 0.001)。然而,AER311-IHA测定的ER水平与DCC测定的ER水平之间的相关性(r = 0.53,P < 0.001)高于1D5-IHA(r = 0.32,P = 0.002)。因此,AER311-IHA可以提供石蜡切片上乳腺癌ER状态的可靠信息,是其他市售单克隆抗体的可接受替代品。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验