Miyahara K, Amitani S, Sohara H, Kurose M, Iwamura H, Toyohira H, Taira A
Division of Cardiology, Shinkyo Hospital, Kagoshima, Japan.
Jpn Circ J. 1996 Dec;60(12):993-7. doi: 10.1253/jcj.60.993.
We report an interesting case of aortic regurgitation. Phonocardiographically, the shape of the diastolic musical murmur in this case changed in each cardiac cycle despite being in sinus rhythm, in the same posture and in the same breathing phase. Experimentally, we were able to obtain a similar noise pattern using an artificial respirator and a hemispherical silicone membrane. We concluded that the irregular and chaotic change in the shape of the diastolic musical murmur in the present case occurred due to irregular swaying of the non-coronary cusp under the influence of the Venturi effect owing to a regurgitant jet stream.
我们报告了一例有趣的主动脉瓣反流病例。在心音图检查中,尽管该病例处于窦性心律、相同体位及相同呼吸阶段,但舒张期音乐样杂音的形态在每个心动周期中都会发生变化。通过实验,我们使用人工呼吸机和半球形硅胶膜能够获得类似的噪声模式。我们得出结论,本例舒张期音乐样杂音形态的不规则且混乱的变化是由于反流喷射流产生的文丘里效应影响下,无冠瓣的不规则摆动所致。