Courbier R, Jausseran J M, Reggi M
Arch Surg. 1977 Sep;112(9):1115-8. doi: 10.1001/archsurg.1977.01370090097021.
Intraoperative arteriography was carried out using a specially constructed operating table and long x-ray film changer that permitted rapid serial exposure of the arterial reconstruction and the distal arteries. During a ten-year period, this method was applied in 1,810 arterial reconstructions, with technical problems being detected in 82 (4.6%) of these patients. The incidence of problems was highest in patients undergoing endarterectomy, where 16.7% of the patients were found to have either residual debris in the cleared segment or areas of stenosis. When bypass grafts were used, technical problems were found in 2.2% of patients and included embolism or thrombosis, graft torsion in vein grafts, stenosis of the distal anastomosis, and the creation of an intimal flap. In the entire series, five patients needed reoperation in the early postoperative period. In three of these, the operative arteriograms had been initially misread.
术中动脉造影采用特制的手术台和长X线胶片换片机进行,该换片机可对动脉重建及远端动脉进行快速连续曝光。在十年期间,该方法应用于1810例动脉重建手术,其中82例(4.6%)患者检测到技术问题。问题发生率在接受内膜切除术的患者中最高,其中16.7%的患者在清除段发现有残留碎片或狭窄区域。使用旁路移植时,2.2%的患者发现技术问题,包括栓塞或血栓形成、静脉移植物扭转、远端吻合口狭窄以及内膜瓣形成。在整个系列中,五名患者在术后早期需要再次手术。其中三名患者的术中动脉造影片最初被误读。