Park J H, Chung J W, Cho Y K, Kim S H, Ahn H, Oh B H
Department of Radiology, Seoul National University College of Medicine, 28 Yongon-Dong, Chongno-Ku, Seoul 110-744, Korea.
Cardiovasc Intervent Radiol. 1997 Mar-Apr;20(2):146-8. doi: 10.1007/s002709900124.
The false channel of a type III aortic dissection caused acute renal ischemia by compression of the origin of the left renal artery in a patient with status post-right nephrectomy. To relieve the ischemia and restore renal function, percutaneous balloon fenestration was performed successfully.