Suppr超能文献

使用非接触式钬:钇铝石榴石激光热角膜成形术矫正准分子原位角膜磨镶术所致远视。

Correction of hyperopia induced by photorefractive keratectomy using non-contact Ho:YAG laser thermal keratoplasty.

作者信息

Alió J L, Ismail M M, Artola A, Pérez Santonja J J

机构信息

Department of Ophthalmology, Instituto Oftalmologico de Alicante, Spain.

出版信息

J Refract Surg. 1997 Jan-Feb;13(1):13-6. doi: 10.3928/1081-597X-19970101-06.

Abstract

PURPOSE

To evaluate the safety and effectiveness of non-contact holmium:YAG laser thermal keratoplasty in correcting hyperopia induced by photorefractive keratectomy (PRK).

METHODS

Non-contact holmium:YAG laser thermal keratoplasty was applied to 14 eyes with significant hyperopia induced by PRK. The mean spherical equivalent refraction before holmium:YAG laser thermal keratoplasty was +4.20 +/- 1.80 diopters (D) (range, +1.75 to +6.25 D). The results were evaluated 12 months after holmium:YAG laser thermal keratoplasty.

RESULTS

No sight-threatening complications occurred. Recovery of spectacle-corrected visual acuity took from 2 to 6 weeks. The immediate significant myopic shift that developed in all eyes gradually receded over 6 to 8 weeks. All eyes were relatively stable after 9 months. At 12 months, there was no statistically significant difference (p < .005) between the mean preoperative spectacle-corrected visual acuity (0.71 +/- 0.12) and the mean postoperative uncorrected visual acuity (0.65 +/- 0.28). At 12 months there was a mean increase of 4.60 +/- 1.20 D in central keratometric power. Total regression did not occur in any eye.

CONCLUSIONS

Non-contact holmium:YAG laser thermal keratoplasty offers a safe and effective alternative to correct PRK-induced hyperopia.

摘要

目的

评估非接触式钬激光热角膜成形术矫正准分子原位角膜磨镶术(PRK)所致远视的安全性和有效性。

方法

对14只因PRK导致明显远视的眼睛实施非接触式钬激光热角膜成形术。钬激光热角膜成形术前平均等效球镜度为+4.20±1.80屈光度(D)(范围为+1.75至+6.25 D)。在钬激光热角膜成形术后12个月评估结果。

结果

未发生威胁视力的并发症。矫正视力恢复时间为2至6周。所有眼睛出现的即刻明显近视性偏移在6至8周内逐渐消退。9个月后所有眼睛相对稳定。12个月时,术前平均矫正视力(0.71±0.12)与术后平均未矫正视力(0.65±0.28)之间无统计学显著差异(p<0.005)。12个月时中央角膜曲率平均增加4.60±1.20 D。没有一只眼睛出现完全回退。

结论

非接触式钬激光热角膜成形术为矫正PRK所致远视提供了一种安全有效的替代方法。