• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Clinical evaluation of a thin bipolar pacing lead.

作者信息

Breivik K, Danilovic D, Ohm O J, Guerola M, Stertman W A, Suntinger A

机构信息

Medical Department A, University School of Medicine, Bergen, Norway.

出版信息

Pacing Clin Electrophysiol. 1997 Mar;20(3 Pt 1):637-46. doi: 10.1111/j.1540-8159.1997.tb03882.x.

DOI:10.1111/j.1540-8159.1997.tb03882.x
PMID:9080490
Abstract

The main disadvantages of bipolar pacing leads have traditionally been related to their relative thickness and stiffness compared to unipolar leads. In a new "drawn filled tube" plus "coated wire" technology, each conductor strand is composed of MP35N tubing filled with silver core and coated with a thin ETFE polymer insulation material. This and parallel winding of single anode and cathode conductors into a single bifilar coil resulted in a bipolar lead (ThinLine, Intermedics) with a body diameter and flexibility similar to unipolar leads. The lead is tined, polyurethane, with the cathode and the anode made of iridium-oxide-coated titanium (IROX). The slotted 8-mm2 cathode tip is coated with polyethylene glycol, a blood soluble material. We present the clinical evaluation results from four pacemaker clinics, where 47 leads (23 atrial-J model 432-04 and 24 ventricular model 430-10) were implanted in 25 patients and followed for up to 2 years. The lead handling characteristics were found to be very satisfactory. Electrical parameters of the leads were measured at implant and noninvasively on postoperative days 1, 2, 21, 42, and months 3, 6, 12, and 24. Mean chronic pulse width thresholds at 2.5 V were 0.14 +/- 0.05 ms in the atrium and 0.10 +/- 0.02 ms in the ventricle, pacing impedances 443 +/- 104 omega and 520 +/- 241 omega, while median electrogram amplitudes were > or = 3.5 mV and > or = 7 mV, respectively. Pacing impedances and thresholds were found to be slightly but statistically significantly higher in unipolar than in bipolar configuration--the findings are explainable by the lead construction. One of 47 leads failed 3 weeks after implant; the conductors were short circuited due to an error during the manufacturing process. We conclude that the new lead thus far has demonstrated appropriate mechanical and electrical characteristics.

摘要

相似文献

1
Clinical evaluation of a thin bipolar pacing lead.
Pacing Clin Electrophysiol. 1997 Mar;20(3 Pt 1):637-46. doi: 10.1111/j.1540-8159.1997.tb03882.x.
2
Bipolar leads for use with permanently implantable cardiac pacing systems: a review of limitations of traditional and coaxial configurations and the development and testing of new conductor, insulation, and electrode designs.用于永久性植入式心脏起搏系统的双极导联:传统和同轴配置的局限性综述以及新型导体、绝缘和电极设计的开发与测试
J Invest Surg. 1997 Jan-Apr;10(1-2):1-15. doi: 10.3109/08941939709032119.
3
Bipolar active fixation atrial leads: comparison of two new lead models.
Pacing Clin Electrophysiol. 1998 Nov;21(11 Pt 2):2285-90. doi: 10.1111/j.1540-8159.1998.tb01168.x.
4
Electrical characteristics of a split cathodal pacing configuration.分体阴极起搏配置的电学特性。
Pacing Clin Electrophysiol. 2003 Dec;26(12):2264-71. doi: 10.1111/j.1540-8159.2003.00357.x.
5
A fractally coated, 1.3 mm2 high impedance pacing electrode.一种具有分形涂层的、面积为1.3平方毫米的高阻抗起搏电极。
Pacing Clin Electrophysiol. 1998 Jun;21(6):1239-46. doi: 10.1111/j.1540-8159.1998.tb00183.x.
6
Clinical experience with passive-fixation coradial bipolar endocardial pacing leads. ThinLine Clinical Investigators.
Pacing Clin Electrophysiol. 1998 Nov;21(11 Pt 2):2291-9. doi: 10.1111/j.1540-8159.1998.tb01169.x.
7
Pacing threshold trends and variability in modern tined leads assessed using high resolution automatic measurements: conversion of pulse width into voltage thresholds.
Pacing Clin Electrophysiol. 1999 Apr;22(4 Pt 1):567-87. doi: 10.1111/j.1540-8159.1999.tb00498.x.
8
Clinical performance of steroid-eluting pacing leads with 1.2-mm2 electrodes.带有1.2平方毫米电极的类固醇洗脱起搏导线的临床性能
Pacing Clin Electrophysiol. 1997 Nov;20(11):2799-809. doi: 10.1111/j.1540-8159.1997.tb05438.x.
9
Comparison of unipolar and bipolar active fixation atrial pacing leads.
Pacing Clin Electrophysiol. 1988 May;11(5):544-9. doi: 10.1111/j.1540-8159.1988.tb04549.x.
10
Initial experience with a co-radial bipolar pacing lead.
Pacing Clin Electrophysiol. 1997 Jul;20(7):1800-7. doi: 10.1111/j.1540-8159.1997.tb03570.x.