Asano J, Suisha F, Takada M, Kawasaki N, Miyazaki S
Faculty of Pharmaceutical Sciences, Health Science University of Hokkaido, Japan.
Biol Pharm Bull. 1997 Mar;20(3):288-91. doi: 10.1248/bpb.20.288.
The effect of pulsed output ultrasound (1 MHz) with on/off ratios of 1:2, 1:4 and 1:9 on transdermal absorption of indomethacin from an ointment was studied in rats. Ultrasound energy was supplied for between 10 and 19 min at a range of intensities (1.0-2.5 W.cm-2), energy levels commonly used for therapeutic purposes. The on/off pulsed ratio, intensity and the time of application were found to play an important role in the transdermal phonophoretic delivery system of indomethacin; 1:2 pulsed output ultrasound appeared to be the most effective in improving the transdermal absorption. The highest penetration was observed at an intensity of 1.0 W.cm-2 and application time of 15 min. With pulsed output it was possible to use higher intensities of ultrasound without increasing skin temperature or damaging skin.
研究了开/关比为1:2、1:4和1:9的脉冲输出超声(1兆赫)对大鼠软膏中吲哚美辛经皮吸收的影响。在一系列强度(1.0 - 2.5瓦·厘米⁻²)下,超声能量供应10至19分钟,这些能量水平常用于治疗目的。发现开/关脉冲比、强度和施加时间在吲哚美辛的经皮超声透入给药系统中起着重要作用;1:2的脉冲输出超声似乎在改善经皮吸收方面最有效。在强度为1.0瓦·厘米⁻²和施加时间为15分钟时观察到最高渗透率。使用脉冲输出可以在不增加皮肤温度或不损伤皮肤的情况下使用更高强度的超声。