Suppr超能文献

Effects of reducing reagents and temperature on conversion of nitrite and nitrate to nitric oxide and detection of NO by chemiluminescence.

作者信息

Yang F, Troncy E, Francoeur M, Vinet B, Vinay P, Czaika G, Blaise G

机构信息

Department of Anesthesia, Hôpital Notre-Dame, Université de Montréal, QC, Canada.

出版信息

Clin Chem. 1997 Apr;43(4):657-62.

PMID:9105269
Abstract

To measure the concentration of nitrites and nitrates by chemiluminescence, we examined the efficiency of five reducing agents [V(III), Mo(VI) + Fe(II), NaI, Ti(III), and Cr(III)] to reduce nitrite (NO2-) and (or) nitrate (NO3-) to nitric oxide (NO). The effect of each reducing agent on the conversion of different amounts of NO2- and (or) NO3- (100-500 pmol, representing concentrations of 0.4 to 2 mu molar) to NO was determined at 20 degrees C for NO2- and at 80 degrees C for NO3-. The effect of temperature from 20 to 90 degrees C on the conversion of a fixed amount of NO2- or NO3- (400 pmol or 1.6 mu molar) to NO was also determined. These five reducing agents are similarly efficient for the conversion of NO2- to NO at 20 degrees C. V(III) and Mo(VI) + Fe(II) can completely reduce NO3- to NO at 80 degrees C. NaI and Cr(III) were unable to convert NO3- to NO. Increased temperature facilitated the conversion of NO3- to NO, rather than that of NO2- to NO. We evaluated the recovery of NO2- and NO3- from plasmas of pig and of dog. Recovery from plasma of both animals was reproducible and near quantitative.