Olscamp A J, Tao S S, Savolaine E R, Ebraheim N A
Department of Orthopaedic Surgery, Medical College of Ohio, Toledo, USA.
Am J Orthop (Belle Mead NJ). 1997 Apr;26(4):294-7.
Previous studies have documented the effectiveness of magnetic resonance imaging for evaluating and following up the development of avascular necrosis of the femoral head. One of the limitations of this technique, however, is the distortion that is encountered with ferromagnetic screws. A traumatic fracture to the femoral head is a risk factor for avascular necrosis. The addition of internal fixation, which is often required in Pipkin-type fractures of the femoral head, creates significant image distortion on magnetic resonance scans used for postoperative follow-up. The artifact and field distortion present in magnetic resonance imaging when ferromagnetic screw fixation is used has been avoided at our institution by the use of titanium hardware. The authors, therefore, recommend the use of titanium screws in the fixation of Pipkin-type fractures in the hip joint.
以往的研究已经证明了磁共振成像在评估和随访股骨头缺血性坏死发展情况方面的有效性。然而,该技术的局限性之一是使用铁磁性螺钉时会出现图像失真。股骨头创伤性骨折是缺血性坏死的一个危险因素。在股骨头Pipkin型骨折中通常需要进行内固定,这会在用于术后随访的磁共振扫描中产生明显的图像失真。在我们机构,通过使用钛合金硬件,避免了在使用铁磁性螺钉固定时磁共振成像中出现的伪影和磁场失真。因此,作者建议在髋关节Pipkin型骨折的固定中使用钛合金螺钉。