Ahrend K D, Hartung E, Dupuis H
Institute of Occupational Health and Social Medicine, Johannes Gutenberg University, Mainz, Germany.
Cent Eur J Public Health. 1995;3 Suppl:85-7.
The vibration sensitivity of the skin at the ten fingertips was tested with 72 chain saw operators examined due to VWF-disease and compared with controls. The vibrotactile perception threshold (frequency f = 125 Hz, load p = 1.3 N) proved to be 3 to 5 times as high for the exposed group compared to controls. There was no correlation between vibration sensitivity and peripheral circulation found in cold provocation test. Two different testing instruments (pallaesthesiometer = vibrotactometer) showed significant differences in results probably due to different technical details of the methods. It may be concluded that a standardization of the instrumentation and method is necessary for testing the vibrotactile perception threshold as a part of the nervous function in a comparable manner.