Accumulating evidence suggests that the ELISA determination of D-Dimer might be a useful tool for the exclusion of deep vein thrombosis (DVT) of lower extremities, because of its high sensitivity and negative predictive value. However, conventional ELISA assay is time-consuming and, therefore, is not suitable for emergency use. To evaluate the accuracy of two rapid assays recently described, 126 consecutive outpatients with the clinical suspicion of DVT underwent the NycoCard D-Dimer and the Instant I.A. D-Dimer determination, using venography as the reference test. In all patients, the conventional ELISA assay was also performed. Venography confirmed the presence of DVT in 30 patients (23.8%), and ruled out the diagnosis in the remaining 96. Instant I.A D-Dimer was positive in 28 patients with DVT (sensitivity, 93.3%), and negative in 90 subjects free from thrombosis (specificity, 93.8%). Nycocard D-Dimer correctly identified 27 patients with DVT (sensitivity 90.0%), and was negative in 77 subjects free from thrombosis (specificity, 80.2%). Sensitivity, specificity, negative and positive predictive values of both tests did not differ from those found with the classic ELISA method. In conclusion, both Instant I.A. D-Dimer and Nycocard D-Dimer assays show a great potential for clinical use.

摘要

越来越多的证据表明,由于ELISA法检测D - 二聚体具有高敏感性和阴性预测价值,它可能是排除下肢深静脉血栓形成(DVT)的一种有用工具。然而,传统的ELISA检测耗时,因此不适合紧急情况使用。为了评估最近描述的两种快速检测方法的准确性,126例临床怀疑DVT的连续门诊患者接受了NycoCard D - 二聚体和即时免疫分析D - 二聚体检测,并以静脉造影作为参考检测。所有患者均进行了传统的ELISA检测。静脉造影证实30例患者(23.8%)存在DVT,其余96例排除诊断。即时免疫分析D - 二聚体在28例DVT患者中呈阳性(敏感性93.3%),在90例无血栓形成的受试者中呈阴性(特异性93.8%)。NycoCard D - 二聚体正确识别出27例DVT患者(敏感性90.0%),在77例无血栓形成的受试者中呈阴性(特异性80.2%)。两种检测方法的敏感性、特异性、阴性和阳性预测值与经典ELISA方法的结果无差异。总之,即时免疫分析D - 二聚体和NycoCard D - 二聚体检测方法在临床应用中均显示出巨大潜力。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验