• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Standard criterion for fluctuations of modulation transfer function in the human eye: application to disposable contact lenses.

作者信息

Lorente A, Pons A M, Malo J, Artigas J M

机构信息

Departament d'Optica, Facultat de Física, Universitat de València, Spain.

出版信息

Ophthalmic Physiol Opt. 1997 May;17(3):267-72.

PMID:9196670
Abstract

It is well known that the modulation transfer function (MTF) characterizes the optical quality of the eye. Recently, some objective techniques have been introduced in order to measure this function in vivo. These techniques could be employed to display the temporal fluctuations of the eye + compensation system and to isolate the effect of the compensation element provided that the standard fluctuations for a normal observer were known. In this work we carry out a study of the MTF of the human eye over a long period of time to quantify the standard fluctuations of the retinal image quality and to establish a standard criterion of normality. We have defined a single quality parameter from each measured MTF to simplify the analysis of the results. We have evaluated this merit function on normal observers three times a day for one month. As expected, random deviations from the mean value of the merit function have been obtained, although fluctuations with no statistical differences of the merit function (P value from ANOVA test P > 0.01) and the standard deviation of these fluctuations (5%) can be chosen as a standard criterion. We have used this result to study the behaviour of a time-varying compensation element: a disposable contact lens. The study of the eye + contact lens system has been carried out with four types of disposable contact lenses for one month. In spite of their generally good behaviour, statistically significant differences from the standard pattern can be observed. This superimposed continuous fluctuation can be due to lens-dependent processes.

摘要

相似文献

1
Standard criterion for fluctuations of modulation transfer function in the human eye: application to disposable contact lenses.
Ophthalmic Physiol Opt. 1997 May;17(3):267-72.
2
Characterization of the visual performance with soft daily wear disposable contact lenses.
Ophthalmic Physiol Opt. 1998 Jan;18(1):40-8.
3
On-eye optical quality of daily disposable contact lenses for different wearing times.不同佩戴时间的日抛型接触镜的眼内光学质量。
Ophthalmic Physiol Opt. 2013 Sep;33(5):581-91. doi: 10.1111/opo.12044. Epub 2013 Mar 19.
4
The effect of contact lens wear on dynamic ocular surface temperature.隐形眼镜佩戴对动态眼表温度的影响。
Cont Lens Anterior Eye. 2005 Mar;28(1):29-36. doi: 10.1016/j.clae.2004.10.001. Epub 2004 Dec 8.
5
Double-pass measurements of retinal image quality in monofocal contact lens wearers.单焦点隐形眼镜佩戴者视网膜图像质量的双程测量。
Ophthalmic Physiol Opt. 1997 Jul;17(4):357-66.
6
Effect of internal lubricating agents of disposable soft contact lenses on higher-order aberrations after blinking.一次性软性隐形眼镜内部润滑剂对眨眼后高阶像差的影响。
Eye Contact Lens. 2008 Mar;34(2):100-5. doi: 10.1097/ICL.0b013e31812e008b.
7
Retinal image quality after microincision intraocular lens implantation.微小切口人工晶状体植入术后的视网膜图像质量
J Cataract Refract Surg. 2005 Aug;31(8):1557-60. doi: 10.1016/j.jcrs.2005.01.026.
8
Tear film surface quality with soft contact lenses using dynamic-area high-speed videokeratoscopy.使用动态区域高速角膜地形图仪评估软性接触镜的泪膜表面质量。
Eye Contact Lens. 2009 Sep;35(5):227-31. doi: 10.1097/ICL.0b013e3181b3350f.
9
Analysis of the optical quality of intraocular lenses.人工晶状体光学质量分析
Invest Ophthalmol Vis Sci. 2004 Aug;45(8):2682-90. doi: 10.1167/iovs.03-1024.
10
Goldmann applanation tonometry over daily disposable contact lens: accuracy and safety of procedure.在日抛型隐形眼镜上进行戈德曼压平眼压测量法:该操作的准确性和安全性
Cont Lens Anterior Eye. 2007 Sep;30(4):233-8; quiz, 260-1. doi: 10.1016/j.clae.2007.06.001. Epub 2007 Aug 10.