Blumenthal M, Grinbaum A, Assia E I
Goldschleger Eye Institute, Sheba Medical Center, Tel-Hashomer, Israel.
J Cataract Refract Surg. 1997 May;23(4):476-9. doi: 10.1016/s0886-3350(97)80202-7.
We describe a method in which constant infusion inflow through an anterior chamber maintainer (ACM) is used to maintain positive intraocular pressure (IOP) during cataract extraction through a self-sealing tunnel incision. A retrospective review of patient records showed that the difference in the incidence of intraoperative suprachoroidal hemorrhage was significantly greater in eyes in which IOP was not constant throughout surgery than in eyes in which IOP was maintained using the ACM system.
我们描述了一种方法,即在通过自闭式隧道切口进行白内障摘除术期间,利用前房维持器(ACM)持续输注流入液来维持眼内压(IOP)为正值。对患者记录的回顾性研究表明,术中脉络膜上腔出血发生率的差异在手术全程IOP不稳定的眼中比在使用ACM系统维持IOP的眼中显著更大。