Short TE MR microscopy: accurate measurement and zonal differentiation of normal hyaline cartilage.

作者信息

Freeman D M, Bergman G, Glover G

机构信息

Hewlett Packard Laboratories, Palo Alto, CA 94304-1392, USA.

出版信息

Magn Reson Med. 1997 Jul;38(1):72-81. doi: 10.1002/mrm.1910380112.

Abstract

The purpose of this study was to use MR imaging to accurately measure the thickness of hyaline cartilage and determine the MR contrast parameters for differentiation of cartilage zones in normal human cartilage samples. Cartilage samples were examined using three dimensional spin-echo MR microscopy at 9.4 T with a voxel size of 31 x 31 x 300 microns. Effects of T2 signal loss, susceptibility, and partial volume on measured thickness of cartilage were investigated. Thickness measurements were obtained on corresponding histological sections for comparison. Optimal contrast parameters for delineation of cartilage zones were evaluated using magnetization transfer, inversion recover, T1, and T2 contrast. T2 relaxation losses were identified as the primary source of discrepancy between the measured thickness of cortical bone and hyaline cartilage. Good contrast for zonal differentiation was obtained using T1 weighting. We conclude that images obtained using short TE MR microscopy can be used to accurately measure cartilage and bone thickness in human specimens, and can demonstrate zones within normal cartilage.