Suppr超能文献

一种新型泪液采集方法:玻璃毛细微量移液器与多孔聚酯棒的比较。

A novel method of tear collection: comparison of glass capillary micropipettes with porous polyester rods.

作者信息

Jones D T, Monroy D, Pflugfelder S C

机构信息

Department of Ophthalmology, Bascom Palmer Eye Institute, University of Miami School of Medicine, Miami, Florida 33136, USA.

出版信息

Cornea. 1997 Jul;16(4):450-8.

PMID:9220244
Abstract

PURPOSE

To develop a rapid, user-friendly method of tear collection to facilitate tear-protein analysis.

METHODS

Tears were collected from a total of 19 normal volunteers without evidence of ocular-surface disease with either porous polyester rods or glass-capillary micropipettes. Tear-collection rate and recovery of two tear proteins, epidermal growth factor (EGF, low abundance) and lactoferrin (LFR, high abundance) were compared between polyester rods and glass-capillary micropipettes. The recovery of LFR and EGF and the stability of these proteins after storage at -70 degrees C were quantitated by specific monoclonal enzyme-linked immunosorbent assay (ELISA).

RESULTS

Polyester rods collected tears an average of 3.9-fold faster than glass-capillary micropipettes (p < 0.001). Both methods were comparable in efficacy of protein recovery. The polyester rods demonstrated a trend toward enhanced recovery, but this difference was not statistically significant (p = 0.12, LFR; p = 0.055, EGF). Analysis of the reliability and reproducibility of the tear-collection assay system revealed that ELISA analysis is highly reproducible, but there is significant day-to-day variation in tear-protein levels of both LFR and EGF for a given volunteer. Both LFR and EGF displayed a trend toward enhanced detection by ELISA shortly after freezing at -70 degrees C and slow decay after storage at -70 degrees C for up to 72 and 105 days, respectively. After stimulation of reflex tearing via the nasolacrimal reflex, LFR levels remained relatively constant, whereas EGF levels for most patients declined and then plateaued.

CONCLUSIONS

Polyester rods provide a more rapid, user-friendly alternative to glass-capillary micropipettes for the collection and analysis of tear fluid and tear proteins. Polyester rods may have greater clinical utility, facilitating routine analysis of the preocular tear film.

摘要

目的

开发一种快速、用户友好的泪液采集方法,以促进泪液蛋白分析。

方法

使用多孔聚酯棒或玻璃毛细管微量移液器,从19名无眼表疾病迹象的正常志愿者中采集泪液。比较聚酯棒和玻璃毛细管微量移液器在泪液采集速率以及两种泪液蛋白(表皮生长因子(EGF,低丰度)和乳铁蛋白(LFR,高丰度))回收率方面的差异。通过特异性单克隆酶联免疫吸附测定(ELISA)对LFR和EGF的回收率以及在-70℃储存后这些蛋白质的稳定性进行定量分析。

结果

聚酯棒采集泪液的平均速度比玻璃毛细管微量移液器快3.9倍(p < 0.001)。两种方法在蛋白质回收效率方面具有可比性。聚酯棒显示出回收率提高的趋势,但这种差异无统计学意义(LFR,p = 0.12;EGF,p = 0.055)。对泪液采集测定系统的可靠性和可重复性分析表明,ELISA分析具有高度可重复性,但对于给定的志愿者,LFR和EGF的泪液蛋白水平在不同日期存在显著差异。LFR和EGF在-70℃冷冻后不久通过ELISA检测均呈现出增强的趋势,在-70℃储存长达72天和105天后分别缓慢下降。通过鼻泪反射刺激反射性流泪后,LFR水平保持相对恒定,而大多数患者的EGF水平下降后趋于平稳。

结论

对于泪液和泪液蛋白的采集与分析,聚酯棒为玻璃毛细管微量移液器提供了一种更快速、用户友好的替代方法。聚酯棒可能具有更大的临床实用性,有助于眼前泪膜的常规分析。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验