• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Adhesion promotion between metadent and a high palladium alloy with a pyrolytically fused porcelain opaque layer.

作者信息

van Putten M C, Culbertson B M

机构信息

Department of Restorative Dentistry, Dental School, University of TexasHealth Science Center at San Antonio, USA.

出版信息

J Prosthodont. 1994 Jun;3(2):79-87. doi: 10.1111/j.1532-849x.1994.tb00133.x.

DOI:10.1111/j.1532-849x.1994.tb00133.x
PMID:9227102
Abstract

PURPOSE

Several authors have reported a preference for the use of high palladium alloys in the construction of implant-fixed partial denture (IFPD) substructures. Heat-polymerized polymethyl methacrylate resins (PMMR) are used to secure denture teeth to IFPD substructures. Metadent (Sun Medical Co, Kyoto, Japan), a heat-polymerized PMMR containing 5% 4-methacryloxyethyl trimellitate anhydride (4-META), could possibly improve the overall design of the prosthesis because this resin adheres to resin and ceramic denture teeth and noble metals. However, adhesive bonding between Metadent and elemental palladium has been shown to be poor. The purpose of this study was to evaluate the potential for adhesive bonding between Metadent, titanate primers, and a ceramic layer pyrolytically fused to a high palladium alloy.

MATERIALS AND METHODS

Five groups of 10 specimens were prepared. A layer of opaque porcelain was baked on all of the specimens under vacuum at 1760 degrees F. The specimens were grouped as follows: (1) Metadent resin processed on ceramic with no primer, (2) Metadent resin with 10% ethyl acetoacetate titanate (DC) processed on ceramic with no primer, (3) Metadent resin with 10% DC processed to ceramic with a 2% tetraisopropyl (TPT) surface primer, (4) 4-Metadent resin with 10% DC processed to ceramic with a 2% isopropyl dimethacryloyl isostearoyl titanate (KR-7) surface primer, and (5) Metadent resin with 10% DC processed to ceramic with a titanium dioxide layer on the opaque and a KR-7 surface primer. The primers were in a methyl methacrylate (MMA) solution. All of the specimens were heat-polymerized under pressure at 212 degrees F for 1 hour. One-half (25) of the specimens (5 from each group) were hydro-thermocycled at 4 degrees C to 55 degrees C, 0.5 minute dwell per bath for 3,000 cycles. All specimens were tested in shear on an MTS Universal machine at cross head speeds of 0.5/mm/min.

RESULTS

The results showed adhesion between the resin-ceramic layer in virtually all groups regardless of thermocycling effects. The control (heat cure without 10% DC and no primer) and the 10% DC with KR-7 and TPT primer groups had an average MPa of 7.5, 7.7, and 7.0, respectively. The failure mode of the specimens was adhesive, with the site of failure being the porcelain-metal interface.

CONCLUSION

It was concluded that adhesion between palladium alloy and Metadent was possible when a ceramic layer was used as an intermediary interface. The limitation seemed to be the adhesion of the ceramic to the metal.

摘要

相似文献

1
Adhesion promotion between metadent and a high palladium alloy with a pyrolytically fused porcelain opaque layer.
J Prosthodont. 1994 Jun;3(2):79-87. doi: 10.1111/j.1532-849x.1994.tb00133.x.
2
The effect of primers on shear bond strength of acrylic resins to different types of metals.引物对丙烯酸树脂与不同类型金属之间的抗剪粘接强度的影响。
J Prosthet Dent. 2010 May;103(5):303-8. doi: 10.1016/S0022-3913(10)60063-7.
3
Evaluation of a new universal primer for ceramics and alloys.新型通用陶瓷和合金引物评估。
J Adhes Dent. 2012 Jun;14(3):275-82. doi: 10.3290/j.jad.a22193.
4
Evaluation of interface characterization and adhesion of glass ceramics to commercially pure titanium and gold alloy after thermal- and mechanical-loading.热加载和机械加载后玻璃陶瓷与商业纯钛及金合金的界面表征及附着力评估
Dent Mater. 2009 Feb;25(2):221-31. doi: 10.1016/j.dental.2008.07.002. Epub 2008 Aug 20.
5
Adhesive bonding of titanium with a titanate coupler and 4-META/MMA-TBB opaque resin.钛与钛酸酯偶联剂和4-META/MMA-TBB不透明树脂的粘结。
J Dent Res. 1990 Sep;69(9):1614-6. doi: 10.1177/00220345900690091601.
6
Effect of thione primers on bonding of noble metal alloys with an adhesive resin.硫酮引物对贵金属合金与粘结树脂粘结的影响。
J Dent. 2000 May;28(4):287-93. doi: 10.1016/s0300-5712(99)00070-6.
7
Effects of interfacial variables on ceramic adherence to cast and machined commercially pure titanium.界面变量对陶瓷与铸造及加工工业纯钛之间附着力的影响。
J Prosthet Dent. 2003 Jul;90(1):10-7. doi: 10.1016/s0022-3913(03)00263-4.
8
An in vitro comparison of tensile bond strengths of noble and base metal alloys to enamel.贵金属合金和贱金属合金与牙釉质拉伸粘结强度的体外比较。
J Prosthet Dent. 2003 Aug;90(2):175-83. doi: 10.1016/s0022-3913(03)00411-6.
9
Effect of laboratory procedures and thermocycling on the shear bond strength of resin-metal bonding systems.实验室操作和热循环对树脂-金属粘结系统剪切粘结强度的影响。
J Prosthet Dent. 2003 Aug;90(2):184-9. doi: 10.1016/s0022-3913(03)00261-0.
10
Effectiveness of adhesive systems for a Co-Cr removable partial denture alloy.用于钴铬可摘局部义齿合金的粘结系统的有效性
J Prosthodont. 1998 Mar;7(1):17-25. doi: 10.1111/j.1532-849x.1998.tb00171.x.