Suppr超能文献

通过激光多普勒血流仪评估糖尿病患者深吸气时的皮肤血管运动反射。一种诊断糖尿病性周围自主神经病变的新方法。

Evaluation of skin vasomotor reflexes in response to deep inspiration in diabetic patients by laser Doppler flowmetry. A new approach to the diagnosis of diabetic peripheral autonomic neuropathy.

作者信息

Aso Y, Inukai T, Takemura Y

机构信息

Department of Medicine, Koshigaya Hospital, Dokkyo University School of Medicine, Saitama, Japan.

出版信息

Diabetes Care. 1997 Aug;20(8):1324-8. doi: 10.2337/diacare.20.8.1324.

Abstract

OBJECTIVE

To evaluate the peripheral sympathetic function in feet of NIDDM patients by means of laser Doppler flowmetry.

RESEARCH DESIGN AND METHODS

After deep inspiration, we measured the vasoconstrictor response in the feet of 51 patients with NIDDM, as compared with those of 20 healthy control subjects, using laser Doppler flowmetry. Subjects whose skin temperature was < 32 degrees C were excluded from our study because a skin temperature of approximately 34 degrees C is the optimal temperature for the evaluation of skin vasomotor reflexes in response to a deep inspiration by laser Doppler flowmetry.

RESULTS

The vasoconstrictor response to deep inspiration in the big toe was significantly decreased in NIDDM patients compared with healthy subjects (26.8 +/- 2.0 vs. 48.3 +/- 18.5%, P < 0.0001). In NIDDM patients, the vasoconstrictor response was positively correlated with the duration of diabetes, the median motor and sensory nerve conduction velocities, the coefficient of variation of the R-R interval at rest, and the postural fall in systolic blood pressure. The vasoconstriction was inversely correlated with the vibratory perception threshold.

CONCLUSIONS

Vasomotor reflexes in the lower limbs were markedly impaired in NIDDM patients. The measurement of vasoconstrictor responses to deep inspiration by using laser Doppler flowmetry is a novel and useful method for detecting peripheral sympathetic failure in diabetic patients.

摘要

目的

通过激光多普勒血流仪评估非胰岛素依赖型糖尿病(NIDDM)患者足部的外周交感神经功能。

研究设计与方法

在深吸气后,我们使用激光多普勒血流仪测量了51例NIDDM患者足部的血管收缩反应,并与20名健康对照者进行比较。皮肤温度低于32摄氏度的受试者被排除在我们的研究之外,因为通过激光多普勒血流仪评估皮肤血管运动反射对深吸气的反应时,约34摄氏度的皮肤温度是最佳温度。

结果

与健康受试者相比,NIDDM患者大脚趾对深吸气的血管收缩反应显著降低(26.8±2.0对48.3±18.5%,P<0.0001)。在NIDDM患者中,血管收缩反应与糖尿病病程、运动和感觉神经传导速度中位数、静息时R-R间期变异系数以及收缩压体位性下降呈正相关。血管收缩与振动觉阈值呈负相关。

结论

NIDDM患者下肢的血管运动反射明显受损。使用激光多普勒血流仪测量深吸气时的血管收缩反应是检测糖尿病患者外周交感神经功能衰竭的一种新颖且有用的方法。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验