Suppr超能文献

一种使用卤化物特异性探针6-甲氧基-N-(3-磺丙基)喹啉鎓(SPQ)测量淋巴细胞内氯离子浓度的流式细胞术方法。

A flow cytometric method for measurement of intracellular chloride concentration in lymphocytes using the halide-specific probe 6-methoxy-N-(3-sulfopropyl) quinolinium (SPQ).

作者信息

Pilas B, Durack G

机构信息

University of Illinois Biotechnology Center, Urbana, 61801, USA.

出版信息

Cytometry. 1997 Aug 1;28(4):316-22.

PMID:9266752
Abstract

A flow cytometry method using the halide-specific fluorescent dye, 6-methoxy-N-(3-sulfopropyl) quinolinium (SPQ), has been developed to measure intracellular chloride concentration in single cells. Collisions with chloride quench the fluorescence of SPQ, making it possible to relate the measured fluorescence intensity to chloride concentration with a Stern-Volmer equation. To demonstrate the method, porcine lymphocytes were loaded in vitro, using a hypotonic method, with 5 mM SPQ. Fluorescence excitation was provided by a UV laser and the fluorescence emission intensity at 485 nm was recorded. Calibration was performed by using 7 microM nigericin (a K/H antiporter) and 10 microM tributyltin (a Cl/OH antiporter) to equilibrate the concentrations of intracellular and extracellular chloride. Calibration measurements were made for chloride concentrations between 0 mM and 140 mM. The calibration produced a Stern-Volmer quenching constant of 16.2 M(-1) which was used to relate measured cell fluorescence to intracellular chloride concentration. The intracellular chloride concentration for fresh porcine lymphocytes was determined to be 56.2 +/- 3.3 mM. Stable loading of cells with 5 mM SPQ was accomplished in 15 minutes, leakage of SPQ from the cells was minimal, and over 95% of the cells remained viable after loading.

摘要

已开发出一种使用卤化物特异性荧光染料6-甲氧基-N-(3-磺丙基)喹啉鎓(SPQ)的流式细胞术方法,用于测量单细胞内的氯离子浓度。与氯离子的碰撞会淬灭SPQ的荧光,从而有可能通过斯特恩-沃尔默方程将测得的荧光强度与氯离子浓度联系起来。为了证明该方法,使用低渗方法在体外将猪淋巴细胞用5 mM SPQ加载。由紫外激光提供荧光激发,并记录485 nm处的荧光发射强度。通过使用7 microM尼日利亚菌素(一种钾/氢反向转运体)和10 microM三丁基锡(一种氯/氢氧根反向转运体)来平衡细胞内和细胞外氯离子的浓度进行校准。对0 mM至140 mM之间的氯离子浓度进行校准测量。校准产生的斯特恩-沃尔默猝灭常数为16.2 M(-1),用于将测得的细胞荧光与细胞内氯离子浓度联系起来。新鲜猪淋巴细胞的细胞内氯离子浓度测定为56.2±3.3 mM。用5 mM SPQ稳定加载细胞在15分钟内完成,SPQ从细胞中的泄漏极少,加载后超过95%的细胞仍保持活力。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验