Ultrasound in the investigation of tubal patency. A meta-analysis of three comparative studies of Echovist-200 including 1007 women.

作者信息

Holz K, Becker R, Schürmann R

机构信息

Clinical Development Diagnostics, Ultrasound Contrast Media, Schering AG Berlin, Germany.

出版信息

Zentralbl Gynakol. 1997;119(8):366-73.

PMID:9286072
Abstract

DESIGN

This study is a meta-analysis of the results of three clinical studies of the ultrasound echo-contrast agent Echovist-200 with transvaginal contrast sonography (HyCoSy) in the demonstration of tubal patency. Results from 1007 patients were included in the analysis, of whom 986 patients were examined for tubal patency. The HyCoSy findings were compared with those of chromolaparoscopy in 428 cases and with those of hysterosalpingography (HSG) in 202.

RESULTS

The results of HyCoSy and chromolaparoscopy were identical in 294 of 428 patients (68.7%) or in 688 of 828 individual tubes (83.1%). HyCoSy showed "false" occlusion in 85 tubes (10.3%) and "false" patency in 55 (6.7%). The results of HyCoSy and HSG were identical in 138 of 202 patients (68.3%) or in 320 of 384 individual tubes (83.3%). HyCoSy showed "false" occlusion in 49 tubes (12.8%) and "false" patency in 15 (3.9%). The findings of chromolaparoscopy and HSG agreed in 49 of 77 patients (63.6%) or in 116 of 152 tubes (76.3%). HSG showed "false" occlusion in 19 (12.5%) tubes and "false" patency in 17 (11.2%).

TOLERANCE

Echovist-200 was well tolerated. The most frequent adverse event was pain, which was mild in 42.3% of patients and severe in 10.1%. Pain was clearly related to tubal occlusion. Other adverse events such as vasovagal reactions or nausea occurred in 7.0% of patients, but the events required treatment in only 1.9%.

摘要

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验