Cost-minimization analysis of intravenous adenosine and dipyridamole in thallous chloride TI 201 SPECT myocardial perfusion imaging.

作者信息

Hilleman D E, Lucas B D, Mohiuddin S M, Holmberg M J

机构信息

Department of Pharmacy Practice, School of Pharmacy and Allied Health Professions, Creighton University, Omaha, NE 68178, USA.

出版信息

Ann Pharmacother. 1997 Sep;31(9):974-9. doi: 10.1177/106002809703100903.

DOI:10.1177/106002809703100903
PMID:9296234
Abstract

OBJECTIVE

To conduct a cost-minimization analysis of intravenous adenosine and intravenous dipyridamole in thallous chloride TI 201 single-photon emission computed tomography (SPECT) myocardial perfusion imaging.

DESIGN

A retrospective, open-label, cost-minimization analysis.

SETTING

University hospital, outpatient nuclear medicine department.

PATIENTS

Eighty-three patients undergoing dipyridamole TI 201 SPECT and 166 patients undergoing adenosine TI 201 SPECT.

MAIN OUTCOME MEASURES

A cost-minimization analysis was conducted using a direct cost accounting approach estimating institutional costs. For the purpose of this study, sensitivity and specificity between adenosine SPECT and dipyridamole SPECT were assumed to be identical. Key costs evaluated included acquisition, administration, monitoring, treatment of adverse effects, follow-up care, and repeat tests.

RESULTS

Adenosine increased heart rate and lowered blood pressure to a significantly greater extent than dipyridamole. The frequency of adverse reactions was not significantly different (p = 0.103) between adenosine (1.64 +/- 1.32 per patient) and dipyridamole (1.36 +/- 1.23 per patient). The frequency of prolonged and late-onset adverse effects was significantly greater for dipyridamole than for adenosine (p < 0.001). The frequency of adverse events requiring medical intervention was statistically greater for dipyridamole (24%) compared with adenosine (5%) (p < 0.00001). Total cost was significantly less for adenosine ($378.50 +/- $128.20 per patient) compared with dipyridamole ($485.60 +/- $230.40). Although adenosine had a significantly greater acquisition cost than dipyridamole (p < 0.0001), administration, monitoring, and adverse reaction costs were significantly less for adenosine than for dipyridamole.

CONCLUSIONS

The cost of using dipyridamole is significantly greater than the cost of using adenosine despite adenosine's high acquisition cost. Adenosine is less expensive to use because of lower administration costs, monitoring costs, and adverse effect costs. Adenosine should be the agent of choice for pharmacologic vasodilation in the setting of myocardial perfusion imaging.

摘要

相似文献

1
Cost-minimization analysis of intravenous adenosine and dipyridamole in thallous chloride TI 201 SPECT myocardial perfusion imaging.
Ann Pharmacother. 1997 Sep;31(9):974-9. doi: 10.1177/106002809703100903.
2
Outcomes and costs of positron emission tomography: comparison of intravenous adenosine and intravenous dipyridamole.
Clin Ther. 1997 May-Jun;19(3):570-81; discussion 538-9. doi: 10.1016/s0149-2918(97)80141-5.
3
Comparison of adenosine and exercise thallium-201 single-photon emission computed tomography (SPECT) myocardial perfusion imaging. The GE SPECT Multicenter Adenosine Study Group.腺苷与运动负荷铊-201单光子发射计算机断层扫描(SPECT)心肌灌注成像的比较。GE SPECT多中心腺苷研究组。
J Am Coll Cardiol. 1992 Feb;19(2):248-57. doi: 10.1016/0735-1097(92)90474-2.
4
Underestimation of extent and severity of coronary artery disease by dipyridamole stress thallium-201 single-photon emission computed tomographic myocardial perfusion imaging in patients taking antianginal drugs.双嘧达莫负荷铊-201单光子发射计算机断层心肌灌注成像对服用抗心绞痛药物患者冠状动脉疾病范围和严重程度的低估
J Am Coll Cardiol. 1998 Jun;31(7):1540-6. doi: 10.1016/s0735-1097(98)00142-9.
5
Cost and clinical consequences of stress/single-photon emission computed tomography testing with specific medications.特定药物应激/单光子发射计算机断层扫描测试的成本和临床后果。
J Med Econ. 2011;14(4):433-9. doi: 10.3111/13696998.2011.584357. Epub 2011 Jun 1.
6
Cost-effectiveness of alternative test strategies for the diagnosis of coronary artery disease.用于冠状动脉疾病诊断的替代检测策略的成本效益
Ann Intern Med. 1999 May 4;130(9):719-28. doi: 10.7326/0003-4819-130-9-199905040-00003.
7
Thallium-201 myocardial imaging in patients with coronary artery disease: comparison of intravenous adenosine and oral dipyridamole.冠心病患者的铊-201心肌显像:静脉注射腺苷与口服双嘧达莫的比较
Ann Pharmacother. 1992 Nov;26(11):1352-7. doi: 10.1177/106002809202601102.
8
Myocardial perfusion imaging laboratory efficiency with the use of regadenoson compared to adenosine and dipyridamole.与腺苷和双嘧达莫相比,瑞加德松在心肌灌注成像实验室中的应用效率。
J Med Econ. 2013;16(4):449-60. doi: 10.3111/13696998.2013.772057. Epub 2013 Feb 25.
9
Intravenous dipyridamole: use in thallous chloride TL 201 stress imaging.静脉注射双嘧达莫:在氯化铊铊201心肌灌注显像中的应用。
DICP. 1991 Oct;25(10):1085-91. doi: 10.1177/106002809102501013.
10
Regadenoson versus Dipyridamole: A Comparison of the Frequency of Adverse Events in Patients Undergoing Myocardial Perfusion Imaging.雷加迪松与双嘧达莫的比较:心肌灌注成像患者不良事件发生率的对比
Pharmacotherapy. 2017 Jun;37(6):657-661. doi: 10.1002/phar.1940. Epub 2017 May 26.