• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Results of heart valve replacement: especially on the selection criteria for valve prostheses and on a new anticoagulation regimen].

作者信息

Sugimura S, Ozawa K, Iriyama T, Hattori Y, Watanabe K, Sai N

出版信息

Rinsho Kyobu Geka. 1989 Jun;9(3):273-9.

PMID:9301929
Abstract

Since March 1981 till the end of 1987, a total of 76 artificial heart valves were implanted in 72 patients. Heart valve prostheses were selected individually according to the patient's needs rather than assigning a single model to every patient. Postoperatively patients were placed on an anticoagulation therapy regimen consisting of reduced-dose warfarin (prothrombin time maintained at 30% of the control) and a small dose (81 mg/day) aspirin. During this period no bioprosthesis was implanted. For aortic valves, Starr-Edwards caged-ball valves were used in 53.1% and St. Jude Medical (SJM) valves in 37.5%. For mitral valves, SJM valves were used in 68%. No mechanical valve failure and no thrombosed valve was encountered. There was one patient-prosthesis missmatch. The incidence of thromboembolism for the entire series was 5/181.2 patient-years. There was 1-2/181.2 patient-years incidence of hemorrhagic complications. These figures were comparable to the ones with conventional warfarin therapy. No intracranial hemorrhage was encountered. Our selection criteria for artificial heart valves and our method of anticoagulation were discussed in detail. We conclude that at present there is no single prosthesis which satisfies all the varying needs of every patient, and the prosthesis which is best suited to that particular patient should be selected. We are generally happy with our current method of postoperative anticoagulation and will continue with this regimen.

摘要

相似文献

1
[Results of heart valve replacement: especially on the selection criteria for valve prostheses and on a new anticoagulation regimen].
Rinsho Kyobu Geka. 1989 Jun;9(3):273-9.
2
Low-dose oral anticoagulation and antiplatelet therapy with St. Jude Medical heart valve prosthesis.使用圣犹达医疗心脏瓣膜假体的低剂量口服抗凝和抗血小板治疗。
J Heart Valve Dis. 1999 Nov;8(6):665-73.
3
Low-dose anticoagulant management of patients with St. Jude Medical mechanical valve prostheses.圣犹达医疗机械瓣膜假体患者的低剂量抗凝管理。
Thorac Cardiovasc Surg. 1993 Feb;41(1):38-42. doi: 10.1055/s-2007-1013818.
4
Pregnancy after mechanical mitral valve replacement.机械二尖瓣置换术后妊娠
J Heart Valve Dis. 2003 May;12(3):370-6.
5
Late incidence and determinants of stroke after aortic and mitral valve replacement.主动脉瓣和二尖瓣置换术后卒中的晚期发生率及决定因素
Ann Thorac Surg. 2004 Jul;78(1):77-83; discussion 83-4. doi: 10.1016/j.athoracsur.2003.12.058.
6
Comparison of anticoagulation regimens after Carpentier-Edwards aortic or mitral valve replacement.Carpentier-Edwards主动脉瓣或二尖瓣置换术后抗凝方案的比较。
Circulation. 1994 Nov;90(5 Pt 2):II214-9.
7
Experience with moderate intensity anticoagulation and aspirin after mechanical valve replacement. A retrospective, non-randomized study.机械瓣膜置换术后中等强度抗凝及阿司匹林治疗的经验。一项回顾性、非随机研究。
J Heart Valve Dis. 1993 May;2(3):302-7.
8
Freedom from complications related to dual ball-and-cage mechanical valve prostheses despite thirty years without anticoagulation.尽管三十年未进行抗凝治疗,但双球笼机械瓣膜假体未出现相关并发症。
Interact Cardiovasc Thorac Surg. 2008 Dec;7(6):1167-9. doi: 10.1510/icvts.2007.172155. Epub 2008 Jul 31.
9
Combined mitral and aortic valve replacement for rheumatic heart disease: fifteen-year follow up and long-term results.风湿性心脏病二尖瓣与主动脉瓣联合置换术:15年随访及长期结果
J Heart Valve Dis. 2009 Mar;18(2):170-9.
10
Twenty-year comparison of tissue and mechanical valve replacement.组织瓣膜置换与机械瓣膜置换的二十年比较
J Thorac Cardiovasc Surg. 2001 Aug;122(2):257-69. doi: 10.1067/mtc.2001.115238.