Hewett T E, Noyes F R, Lee M D
Cincinnati Sportsmedicine and Orthopaedic Center, Deaconess Hospital, OH 45219, USA.
Am J Sports Med. 1997 Sep-Oct;25(5):648-55. doi: 10.1177/036354659702500510.
Stress radiography was performed on 21 patients with unilateral posterior cruciate ligament tears: 10 complete and 11 partial. An 89-N posterior load was applied to the proximal tibia and a lateral radiograph was taken of each knee in 70 degrees of flexion. The relative amount of sagittal translation (involved minus noninvolved) was determined at both the medial and lateral tibial plateaus from the radiographic films. Arthrometric (KT-1000 arthrometer) and posterior drawer tests were also performed. The mean relative posterior translation averaged 12.2 +/- 3.7 mm for knees with complete tears. Arthrometer testing of the same knees showed 7.6 +/- 2.5 mm of increased translation, and posterior drawer testing showed 9.2 +/- 3.3 mm of increased dropback. Stress radiographic results were statistically similar to the electrogoniometric measurements in cadaveric knees. In knees with a partially torn posterior cruciate ligament, mean relative translation measured on stress radiographic was 5.6 +/- 1.5 mm, which was significantly different from that for knees with complete ruptures. The arthrometer and posterior drawer test data were not significantly different for knees with complete and partial tears. Stress radiography is superior to both the arthrometer and clinical posterior drawer testing for determining posterior cruciate ligament status. Eight millimeters of more of increased posterior translation on stress radiographs is indicative of complete rupture.
对21例单侧后交叉韧带撕裂患者进行了应力X线摄影:其中10例为完全撕裂,11例为部分撕裂。对胫骨近端施加89 N的后向负荷,并在屈膝70度时对每个膝关节拍摄外侧X线片。根据X线片确定内侧和外侧胫骨平台矢状面平移的相对量(患侧减去健侧)。还进行了关节测量(KT - 1000关节测量仪)和后抽屉试验。完全撕裂膝关节的平均相对后向平移为12.2±3.7 mm。对相同膝关节进行关节测量仪测试显示平移增加7.6±2.5 mm,后抽屉试验显示后坠增加9.2±3.3 mm。应力X线摄影结果与尸体膝关节的电子测角计测量结果在统计学上相似。在部分撕裂后交叉韧带的膝关节中,应力X线摄影测量的平均相对平移为5.6±1.5 mm,这与完全撕裂的膝关节有显著差异。完全撕裂和部分撕裂膝关节的关节测量仪和后抽屉试验数据无显著差异。在确定后交叉韧带状态方面,应力X线摄影优于关节测量仪和临床后抽屉试验。应力X线片上后向平移增加8毫米以上提示完全断裂。