Abstract

The objective of this study was to examine the interaction between silicone oil and silicone intraocular lenses (IOLs) in vitro. Six types of silicone IOLs were placed in silicone oil (1000 or 5000 centistokes) for 1 minute, 7 days, and 420 days. Slit-lamp examination, target photographs, and opacity measurements were performed. Optical measurements were repeated in a balanced salt solution after removal from the oil. The IOL surface was examined through scanning electron microscopy, and surface irregularities underwent x-ray spectroscopy. No changes were observed while the IOLs were stored in silicone oil, but in the balanced salt solution, the IOLs were observed to have a layer of silicone oil droplets that reduced the optical quality. Scanning electron microscopy showed that oil-coated foreign body particles were simulating IOL surface defects. After ultrasonic cleaning with ethanol, the oil layer was broken, and no damage to the IOL surface could be detected. The length of exposure to silicone oil, the type of oil, and the type of IOL were found to have no bearing on the interaction between silicone oil and silicone IOLs. Although no surface damage is incurred by silicone IOLs from silicone oil, the reduction in optical quality and fundus view due to remnant oil droplets seems to indicate that complex cases requiring silicone oil injection may contraindicate IOLs made of silicone.

摘要

本研究的目的是在体外检测硅油与硅酮人工晶状体(IOL)之间的相互作用。将六种类型的硅酮IOL置于硅油(1000或5000厘沲)中1分钟、7天和420天。进行裂隙灯检查、拍摄目标照片并测量混浊度。从油中取出后,在平衡盐溶液中重复进行光学测量。通过扫描电子显微镜检查IOL表面,并对表面不规则处进行X射线光谱分析。IOL储存在硅油中时未观察到变化,但在平衡盐溶液中,观察到IOL表面有一层硅油滴,这降低了光学质量。扫描电子显微镜显示,油包被的异物颗粒模拟了IOL表面缺陷。用乙醇超声清洗后,油层破裂,未检测到对IOL表面的损伤。发现硅油暴露时间、油的类型和IOL的类型与硅油和硅酮IOL之间的相互作用无关。尽管硅酮IOL不会因硅油而产生表面损伤,但由于残留油滴导致的光学质量下降和眼底观察受限似乎表明,需要注入硅油的复杂病例可能不宜使用硅酮制成的IOL。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验