Hickey J L, Reist P C
Am Ind Hyg Assoc J. 1977 Nov;38(11):613-21. doi: 10.1080/00028897708984405.
A one-compartment exponential models is described which predicts "equal protection", based on biological uptake rates, for unusual air contaminant exposure situations as compared to a "normal" exposure of five 8-hour days per week. This is done by equating peak body burdens resulting from a normal and an unusual exposure, in terms of an adjustment factor applied to the normal exposure limit for an air contaminant. This factor predicts the highest allowable concentration in an unusual exposure situation which will not result in a higher-than normal body accumulation of the inhaled substance. Graphs and formulae are provided for determining adjustment factors for anticipated unusual exposure schedules. The model's predictions and published data are compared.
本文描述了一种单室指数模型,该模型基于生物摄取率预测与每周五个8小时的“正常”暴露相比,异常空气污染物暴露情况下的“等效防护”。这是通过将正常暴露和异常暴露产生的峰值身体负荷相等来实现的,即应用于空气污染物正常暴露限值的调整因子。该因子预测了异常暴露情况下不会导致吸入物质身体积累高于正常水平的最高允许浓度。提供了图表和公式来确定预期异常暴露时间表的调整因子。并将该模型的预测结果与已发表的数据进行了比较。