Suppr超能文献

远程电子血液释放系统。

Remote electronic blood release system.

作者信息

Cox C, Enno A, Deveridge S, Seldon M, Richards R, Martens V, Woodford P

机构信息

Haematology Division, Hunter Area Pathology Service, Newcastle, New South Wales, Australia.

出版信息

Transfusion. 1997 Sep;37(9):960-4. doi: 10.1046/j.1537-2995.1997.37997454025.x.

Abstract

BACKGROUND

The Hunter Area Pathology Service provides transfusion services to 4 metropolitan and 11 rural hospitals in Australia. To improve blood availability, conserve blood stocks, and reduce crossmatch-to-transfusion ratios, a networked electronic blood release system (EBRS) has been developed for computer cross-matching within the laboratory and at sites remote from the transfusion laboratory. It is innovative, in that non-laboratory staffs have been trained to release computer-matched blood at remote hospitals without transfusion laboratories.

STUDY DESIGN AND METHODS

The EBRS software was tested and validated according to the Australian software standards AS 3563.1 and 3563.2 (1991). Over 7000 units were released by the EBRS in a laboratory trial conducted in conjunction with the conventional immediate-spin crossmatch. A further, 12-month study was conducted within the laboratory before the staged implementation of the EBRS at the remote hospitals.

RESULTS

The EBRS has resulted in 1) a 25-percent reduction in the number of units requested by the medical staff, resulting from the reduction in time needed to provide compatible blood due to the elimination of the serologic crossmatch; 2) better blood stock management (reducing outdated red cell units by 30%); and 3) significant savings in laboratory workload (savings of approximately 100 hours/month). In addition, the rapid availability of computer-crossmatched red cells in emergency situations has enhanced patient safety.

CONCLUSION

The EBRS is a safe and efficient means of providing red cells within the laboratory and at remote hospitals without laboratory services.

摘要

背景

猎人地区病理服务中心为澳大利亚的4家都市医院和11家乡村医院提供输血服务。为提高血液供应、保存血库并降低交叉配血与输血比例,已开发出一种联网电子血液发放系统(EBRS),用于实验室内部及远离输血实验室的地点进行计算机交叉配血。其创新之处在于,已培训非实验室工作人员在无输血实验室的偏远医院发放计算机匹配的血液。

研究设计与方法

EBRS软件依据澳大利亚软件标准AS 3563.1和3563.2(1991)进行了测试和验证。在与传统立即离心交叉配血联合开展的实验室试验中,EBRS发放了超过7000单位的血液。在偏远医院分阶段实施EBRS之前,在实验室内部又进行了为期12个月的研究。

结果

EBRS带来了以下成效:1)由于消除了血清学交叉配血,提供相合血液所需时间减少,医务人员申请的单位数量减少了25%;2)更好地管理血库(将过期红细胞单位减少了30%);3)显著节省实验室工作量(每月节省约100小时)。此外,在紧急情况下计算机交叉配血红细胞的快速可得性提高了患者安全性。

结论

EBRS是在实验室内部及无实验室服务的偏远医院提供红细胞的一种安全、高效手段。